background image

Fitting Instructions

Thank you for purchasing this HiB Novum product.

Please read through these instructions carefully and refer back to 
them during installation to ensure that your product is fitted safely 
and that it retains its high quality finish.

GENESIS FITTED FURNITURE

Basin Unit: 

Art No. NF02SBU50*** / NF02SBU60***

BTW Unit: 

Art No. NF02SBTW50*** / NF02SBTW60*** 

Single Door Unit: 

Art No. NF02SSDU30*** 

Three Drawer Unit: 

Art No. NF02S3DR30***

Open Shelf  Unit: 

Art No. NF01SOS20***  

End Panels: 

Art No. NF01SEP*** 

Infill Panels: 

Art No. NF01IP20***  

Plinth: 

Art No. NF01PL100*** / NF01PL150*** / NF01IP200***

MBL - Midnight Blue | DEM - Dark Emerald | CGR - Carbon Grey | 
MWH - Matt White | SWO - Sherwood Oak

 FI

#03 020 

 R

220422  

Ver 

1.0 June 2022

Summary of Contents for Novum NF01SOS20 Series

Page 1: ...uality finish GENESIS FITTED FURNITURE Basin Unit Art No NF02SBU50 NF02SBU60 BTW Unit Art No NF02SBTW50 NF02SBTW60 Single Door Unit Art No NF02SSDU30 Three Drawer Unit Art No NF02S3DR30 Open Shelf Unit Art No NF01SOS20 End Panels Art No NF01SEP Infill Panels Art No NF01IP20 Plinth Art No NF01PL100 NF01PL150 NF01IP200 MBL Midnight Blue DEM Dark Emerald CGR Carbon Grey MWH Matt White SWO Sherwood Oa...

Page 2: ...ng onto other substrate ensure appropriate fixing and batons are used if required and the load bearing of the wall is sufficient When drilling and cutting use appropriate eye protection and wear an appropriate dust mask Take care when using power tools near water the use of a residual current device RCD is advised Beware of hidden cables or pipes Take care if drilling on tiled surfaces in case the...

Page 3: ...ll Hung Installation Door Installation Top Panel Installation BTW Front Panel Installation Drawer Installation Handle Installation Care Maintenance Aftercare Screwdriver Pencil Silicone Tape Fine Tooth Saw Suitable Drill Bit Tape Measure Clamps Eye Protection Spirit Level Dust Mask Drill ...

Page 4: ...4 Figures Fig 1 Carcass Leg Installation Fig 2 BTW Leg Installation Fig 3 Plinth Height Fig 4 Connecting Units Standard Plinth H150mm Basin Unit BTW Unit ...

Page 5: ...ing the feet The HiB standard plinth height is 15cm see Fig 3 9 Position the units together in the configuration required against the wall Using a suitably sized spirit level adjust the feet to level the units 10 Clamp the units together Using the screws and pre drilled holes provided secure the units together see Fig 4 11 Check the level of the units using a suitable spirit level and adjust the f...

Page 6: ...6 Figures Fig 5 Plinth Measurements Fig 6 Plinth Return Fig 7 Plinth Bracket Installation Plinth Return W65mm Basin Unit BTW Unit ...

Page 7: ...5mm see Fig 6 3 Always double check measurements before cutting Cut the plinth to size 4 Measure and mark the carcass leg centres on the back face of the plinth See Fig 7 5 Fix the brackets to the plinth using the screws provided 6 If a plinth return is required fix to the plinth in the appropriate location using the screws provided 7 Prior to installing seal all cut edges using the sealant provid...

Page 8: ...8 Figures Fig 8 Recommended Install Height Fig 9 Measure Cut Panel Fig 10 Seal cut edges Fig 11 Hanger Adjustment 830mm 1 Loosen screw 2 Adjust furniture postion 3 Tighten screw ...

Page 9: ...ized spirit level align the units and secure together using the predrilled holes and screws provided See Fig 11 for hanger adjustment 6 Secure the units to the wall 7 Slide the back panel back into position and replace shelves 8 Measure and cut any end panels and infill panels required see Fig 9 Seal all cut edges see Fig 10 HiB recommends positioning the cut edge at the top of the unit Screws and...

Page 10: ...te Fig 13 Door Adjustment Move door s up down Move door away towards the cabinet Move door s left right Move door s up down Move door away towards the cabinet Move door s left right Fig 14 Top Panel Fitting Fig 15 BTW Front Panel Fitting ...

Page 11: ...ote of the left hand right hand orientation prior to installation 3 Reattach the hinges to the hinge plates 4 Adjust the hinges as required see Fig 13 Top Panel Installation BTW Front Panel Installation 1 Align the clips on the top panel with the clips on the carcass 2 Push the top panel into the clips to secure see Fig 14 1 The BTW front panel is designed to suit a 15cm plinth height 2 Secure the...

Page 12: ...12 Figures Fig 16 Drawer Runner Rear Hooks Fig 17 Locator Pin Adjustment Wheel Fig 18 Drawer Front Adjustment Locator Pin Adjustment Wheel 1 Loosen screw 2 Adjust drawer front 3 Tighten screw ...

Page 13: ... over tighten Drawer Installation and Adjustment 1 HiB recommends fixing handles to the drawer box prior to installing the drawers See the Handle Installation section below 2 Align the drawer onto the runners ensuring the rear hooks are located in the holes on the rear of the drawer box see Fig 16 3 Ensure that the locator pin on the front of the runner see Fig 17 is aligned with the hole predrill...

Page 14: ... solvents Ensure adequate ventilation is maintained in the bathroom Handles HiB recommends cleaning with the use of a dry lint free cloth or wiping the product using a soft cloth with beeswax Under no circumstances should any form of metal cleaner aerosol spray cleaner or solvent based abrasive cleaning solutions be applied to our products as these can remove protective lacquers If such cleaning a...

Page 15: ...15 hib co uk ...

Page 16: ...te but we do try and make sure they are as accurate as possible In the interest of continuous product development HiB reserves the right to alter specifications as necessary E OE T 44 0 20 8441 0352 F 44 0 20 8441 0219 E sales hib co uk hib co uk Building 3 North London Business Park Oakleigh Road South New Southgate London N11 1GN ...

Reviews: