FRU Replacement Guide
5 Storage Interconnect Replaceable Units
64
b) Type
enable
to enter the Privileged EXEC command mode.
(Routing)>enable
c) Type
configure
to enter the Privileged CONF command mode.
(Routing)#configure
(Routing) (Config)#
d) Copy the entire contents of your modified switch configuration file, and paste it into the telnet session.
e) Save the new configuration.
(Routing)#write memory
Are you sure you want to save? (y/n)
y
Config file 'startup-config' created successfully.
Configuration Saved!
(Routing)#
This operation may take a few minutes. Management interfaces are not available during this time.
f) Verify that the settings on the switch match your configuration file.
(Routing)#show startup-config
3.
Remove the two blanking plates from the top front of the rack.
4.
Identify the faulty Storage Interconnect. It is a TOR switch.
Figure 37: Location of Storage Interconnect Switches: [1]
5.
Power off the faulty Storage Interconnect:
Disconnect the power cords on the back of the faulty Storage Interconnect.
6.
Remove the faulty Storage Interconnect from the rack.
a) Disconnect the labeled network cables from the Storage Interconnect.
b) Unscrew the mounting screws from the Storage Interconnect.