FRU Replacement Guide
3 Controller Node Replaceable Units
18
b) Install the disk into the corresponding slot in the new chassis.
Figure 4: Controller Node, Front
7.
Install the new chassis into the rack.
a) Mount the new chassis onto the rack slides and slide it into the rack.
Caution:
Mounting the chassis is a two person task.
b) Tighten the rack mounting screws to secure the chassis to the rack.
c) Reconnect the five network cables to the chassis ports.
The network cables are labeled.
• Connect the cable labeled
CNx.
N1
.SW1.Nxx
(with SFP+ optical transceiver attached) to the port labeled
N1
in the image below.
• Connect the cable labeled
CNx.
N2
.SW1.Nxx
to the port labeled
N2
in the image below.
• Connect the cable labeled
CNx.
N3
.SW2.Nxx
to the port labeled
N3
in the image below.
• Connect the cable labeled
CNx.
N4
.SW1.Nxx
(with SFP+ optical transceiver attached) to the port labeled
N4
in the image below.
• Connect the cable labeled
CNx.
M2
.SW1.Nxx
to the port labeled
M2
in the image below.
Figure 5: Controller Node, Back
d) Reconnect the power cords.
8.
Get the MAC address of the new chassis IPMI NIC from the BIOS.
a) Connect a VGA monitor and USB keyboard to the new chassis.
b) Power on the new chassis.
The power button is located on the chassis front control panel.
c) At power up, press
Del
to enter into the system BIOS.
d) In the system BIOS, navigate to
IPMI
>
BMC Network Configuration
>
.
e) Record
Station MAC Address
in your work table under
IPMI MAC Address of Node
.
f) Exit the BIOS without saving any changes by pressing the
ESC
.
The boot process continues.
g) Disconnect the VGA monitor and USB keyboard from the new chassis.