4.4.3 SBAS Configuration via Terminal
The LD8 SBAS mode can be enabled or disabled via the terminal.
The SBAS positioning mode can be enabled by entering:
SBASCONTROL ENABLE AUTO
The SBAS positioning mode can be disabled by entering:
SBASCONTROL DISABLE
4.4.4 Heading Offset and Output Frequency Via WebUI
The heading of fset and the heading output rate can be configured within the WebUI by navigating to
Configuration > Heading
. The heading offset value can be set between -180
o
and +180
o
. The output rate can
be set between 1Hz and 20Hz (this does not apply to the HDT output message). Click
Apply
to confirm any
changes.
4.4.5 Heading Offset and Output Frequency via Terminal
A heading offset and the heading output rate can also be configured via terminal. The heading offset value can
be set between -180
o
and +180
o
. The heading offset can be added by entering:
HEADINGOFFSET [headingoffsetindeg]
The output rate can be set between 1Hz and 20Hz (this does not apply to the HDT output message). The last
value of the LOG message is the output rate field (1 = 1Hz, 0.5 = 2Hz, 0.2 = 5Hz, 0.1 = 10Hz, 0.05 = 20 Hz).
The output rate can be set by entering:
LOG COM1 GPHDTDUALANTENNA ONTIME 1