You can configure the MGMT port with the
set network baseio=
GEOID
RMC command.
NOTE: For full flexibility to redefine nPars in the future without adding LAN cables, connect all MGMT ports on the
Base and Partitionable Chassis to the management LAN.
• For a non-partitionable system, consisting of a Base Chassis and additional Expansion Chassis, connect the MGMT
port on the Base Chassis to the management LAN for JViewer communication.
• For a partitionable system, connect the MGMT port on the lowermost, monarch chassis for each nPar to the
management LAN.
Configuring the RMC on the network
Prerequisites
The manageability network must be a private server management network within a corporate LAN.
To connect to the RMC, choose one of these two methods:
•
USB—For more information, see Connecting the RMC to the network through a USB port.
•
AUX with cable—For more information, see Connecting the RMC to the network through an AUX with LAN cable.
More information
Connecting the RMC to the network through a USB port
Connecting the RMC to the network through an AUX with LAN cable
Configuring the HPE Superdome Flex Server
18