NOTE:
When library control path failover is first enabled, the hardware address for the library will change.
Windows example: Bus Number 0, Target ID 0, LUN 1 becomes Bus Number 0, Target Id 2, LUN 0
Linux example:
/dev/sg3 HP MSL G3 Series 7.41
becomes
/dev/sg5 HP MSL G3 Series
7.41
If the library detects a situation when it is necessary to remove the primary master drive or force a failover,
power off the drive from the RMI
Configuration > Drive 1 (LUN)
screen. This action will disable the drive
and pass the library control path to the alternative drive. If the disabled drive is replaced with a new drive,
the library LUN stays with the alternative drive until manually reassigned back with
RMI Configuration >
System > Library LUN hosted by Drive
.
• Alternative Drive for Library Control Path — If the library is configured for library control path failover,
select the drive number of the alternative drive.
The Configuration > Security page
From the
Configuration > Security
page you can configure encryption features.
Figure 41: The Configuration > Security page
USB MSL Encryption Kit Configuration
For information about configuring and using the encryption kit, see the encryption kit user guide, which is
available from the Hewlett Packard Enterprise Information Library:
http://www.hpe.com/info/storage/docs
KMIP Encryption Configuration
For instructions on configuring the KMIP feature, see the HPE StoreEver MSL Tape Libraries Encryption Key
Server Configuration Guide, available from the Enterprise Information Library:
The Configuration > Drive page
The
Configuration > Drive
page shows the current configuration of all drives and allows modification to the
configuration. You can also select
Power on
through this page.