Input Requirements
• MSL2024:100 - 240V AC, 1300 - 700mA, 50/60Hz
• MSL4048, MSL8048 and MSL8096: 100 - 240V AC, 2500 - 1300mA, 50/60Hz
Regulatory specifications
Table 48: CSA test conditions
Characteristic
Tested condition or value
Equipment mobility
Stationary (rack-mount or desk-top)
Connection to the mains
Pluggable — Type A
Operating condition
Continuous
Access location
Operator accessible
Over voltage category (OVC)
OVC II
Mains supply tolerance (%) or absolute
mains supply values
-10%, +6%
Tested for IT power systems
No
IT testing, phase-phase voltage (V)
N/A
Class of equipment
Class I
Considered current rating (A)
20 A (branch circuit protection)
Pollution degree (PD)
PD 2
IP protection class
IPX0
Altitude during operation (m)
Max 2000
Altitude of test laboratory (m)
38
Mass of equipment (kg)
Max 25 kg
Manufacturer's Declared Ambient (°C)
40 °C
NOTE:
The CSA test conditions might differ from the product specification limits.
Regulatory specifications