Procedure
1.
From the Home screen, press
Previous
or
Next
until the screen displays
Support
. Press
Enter
to select.
2.
Press
Previous
or
Next
until the screen displays
Run Demo
. Press
Enter
to select.
3.
Enter the administrator password if prompted.
4.
Use
Previous
and
Next
to select the number of cycles: 270, 540, 1080, or Endless. Press
Enter
to start
the demonstration.
5.
While the test is running, the first line of the screen displays
Demo Test
. The second line displays the
number of cycles completed and the number of errors. The
Ready
LED blinks until the test is complete.
Running the slot to slot test (Support > Run Slot To Slot Test)
Use this option to verify that the robot can move media in and out of each of the magazine slots.
To stop the slot to slot test, press the
Cancel
button.
NOTE:
At the end of the test, the cartridges are NOT returned to their original slots.
Prerequisites
Administrator password
Procedure
1.
From the Home screen, press
Previous
or
Next
until the screen displays
Support
. Press
Enter
to select.
2.
Press
Previous
or
Next
until the screen displays
Run Slot To Slot Test
. Press
Enter
to select.
3.
Enter the administrator password, if prompted.
4.
Press
Previous
or
Next
until the screen displays
Select Number of Cycles.
Use
Previous
or
Next
to
select the number of cycles: 270, 540, 1080, or Endless. Press
Enter
.
5.
While the test is running, the screen displays progress as shown:
Run Slot To Slot
. The second line on
the display shows the number of cycles completed. The
Ready
LED blinks until the test is complete.
6.
When the test is complete, the screen displays the number of cycles completed and the number of errors.
If the test failed, press
Enter
to display the error and message describing the cause.
Running the wellness test (Support > Run Wellness Test)
Use this option to check the health of the library for the specified number of loops. If a failure occurs during
the test, check the error code and failure message for more information. Access to this feature requires the
administrator password. For more information about the wellness test, see
on page 163.
For complete testing, enable the mailslot and ensure that each top-row corner slot contains a tape cartridge.
During the test, the library will open the mailslot and ask you to insert a tape cartridge. You can use any
compatible Ultrium data tape cartridge for this test.
IMPORTANT:
The library will remove any tape cartridges from tape drives and go offline when running the wellness
test. Verify that any applications using the library have completed before starting the wellness test.
To stop the wellness test, press the
Cancel
button.
118