Installing the Switch
Installation Procedure
2-5
.
2.
When the switch is powered on, it performs its diagnostic self test. The self test takes approximately 45
seconds to complete. Check the LEDs on the switch as described below.
Self Test LED Behavior
●
During the self test:
○
Initially, the
Power/Fault
,
Locator
, and all port LEDs turn on.
○
After several seconds, the
Power/Fault
and
Locator
LEDs remain on, and the port LEDs turn off.
Then each port
Link
LED is sequentially turned on, then off.
○
The
Locator
LED turns off when the self test completes.
●
When the self test completes successfully:
○
The
Power/Fault
LED remains on (green).
○
The
Locator
LED stays off.
○
The port LEDs on the front of the switch go into their normal operational mode:
-
If the ports are connected to active network devices, the
Link/Act
LEDs stay on or may be
blinking to indicate port activity. The
Spd
LEDs turn on for 10000 Mbps links, blink for 1000
Mbps links, or stay off for 10/100 Mbps links. On the PoE+ switches, the
Mode
LEDs behave
according to the mode selected. In the default mode (
Spd
), the
Mode
LEDs should be on for
10000 Mbps links, blink for 1000 Mbps links, or stay off for 100 Mbps links.
-
If the ports are not connected to active network devices, the
Link/Act
and
Spd
LEDs will stay
off.
If the LED display is different than what is described above, the self test has not completed correctly.
Refer to “
” on page 4-1 for diagnostic help.
3.
Remove power to the switch before mounting.
NOTE:
The Hewlett Packard Enterprise 1850 OfficeConnect switches do not have a power switch. They are
powered on when the power cord is connected to the switch and to a power source. For safety, the power
outlet should be located near the switch installation.
The switches automatically adjusts to any voltage between 100-127 or 200-240 volts and either 50 or 60
Hz. There are no voltage range settings required.
Connect the power cord
to the switch and an AC
power outlet
Summary of Contents for OfficeConnect 1850 2XGT
Page 5: ...iii D Warranty Information D 1...
Page 6: ...iv...
Page 14: ...Switch Overview Switch Features 1 8...
Page 28: ...Installing the Switch Installation Procedure 2 14...
Page 32: ...Configuring the Switch Where to Go From Here 3 4...
Page 48: ...Specifications Twisted Pair Cable Connector Pin Outs A 12...
Page 50: ...Safety and Regulatory Information for the OfficeConnect 1850 Switch Series B 2...
Page 54: ...Support and Other Resources Documentation feedback C 4...
Page 56: ...Warranty Information D 2...