SSB2
RAID Manager
command
Cause of error
97DA
paircreate, mount
snapshot
The command ended abnormally because the T10 PI settings for the
P-VOL and S-VOL did not match.
97DD
unmount snapshot/
replace snapshot
The command ended abnormally because you specified a pair to
which an S-VOL is not assigned.
97DE
mount snapshot/
unmount snapshot/
replace snapshot
The operation failed because different DKCMAIN microcode versions
are mixed. Confirm DKCMAIN microcode version.
97DF
mount snapshot
The command ended abnormally because you specified an S-VOL
that is assigned to a pair.
97F1
replace snapshot
The command ended abnormally because the pair cannot be
identified from snapshot data and the P-VOL that you specified.
97F1
mount snapshot/
replace snapshot
The command ended abnormally because you specified a pair to
which an S-VOL is assigned.
97FA
unmount snapshot/
replace snapshot
The command ended abnormally because you specified an S-VOL
that is not assigned to a pair.
B912
paircreate, pairsplit,
pairresync
The FS pair task failed because you specified the incorrect S-VOL.
B9A7
All commands
You cannot retrieve the consistency group information because FS is
not installed.
FF58
pairsplit, pairresync,
pairresync -restore
The command ended abnormally because the specified pair is a
cascaded pair.
FF59
paircreate
The command ended abnormally because the specified P-VOL is
used by a cascaded pair.
FF6D
paircreate
The command ended abnormally because the specified P-VOL is
used by a cascaded pair.
FF72
paircreate, pairsplit,
pairresync,
pairresync -restore
The Fast Snap pair task failed because a snapshot tree is being
deleted.
FF7A
paircreate
The Fast Snap pair could not be created because the V-VOL capacity
exceeded the amount reserved for the pool.
FF7C
paircreate
The Fast Snap pair whose snapshot data is stored in the THP pool
could not be created because system option mode 1120 is set to ON.
Notes on using Fast Snap primary volumes as Continuous Access
Synchronous, Business Copy, or Continuous Access Journal pair volumes
Following are possible reasons why the pair status cannot be changed:
206
Notes on using Fast Snap primary volumes as Continuous Access Synchronous, Business Copy, or
Continuous Access Journal pair volumes
Summary of Contents for HPE XP7
Page 7: ...Documentation feedback 311 Contents 7...
Page 24: ...24 Overview of Fast Snap...
Page 109: ...2 In the Replication window click Edit Options Local Replication Configuring Fast Snap 109...
Page 186: ...186 Troubleshooting Fast Snap...
Page 187: ...Troubleshooting Fast Snap 187...
Page 214: ...The following table lists the items on this tab 214 Fast Snap GUI windows and wizards...