U
SER’S MANUAL |
ERGO-S
11
4.9 Magnetic Belt Clip (if equipped)
The practical magnetic belt clip allows the user to hang the ERGO-S transmitter to any steel surface and continue operation hands free or
store the transmitter hung vertically when not in use and have easy access to it.
4.10 Cable Control (optional)
The Ergo-S can also be used either wirelessly or via cable control. When the tether is connected, all wireless communication will be
disabled and the telegram will be sent via the cable through the RS232 or CAN bus, depending on the chosen configuration. The tether
cable is connected directly to a battery enclosure and this contains a particular module which must be configured via Hetronic PC-Link.
Refer to Programming and Service Manual for instructions.
The following standard cable options are available to choose from depending on the application. However, customized variants can also be
ordered.
a)
10m CAN cable without termination jumper (#1051512510)
b)
10m CAN cable with termination jumper (#1051512610)
c)
10m RS232 cable (#1051513510)
4.11 Start-Up Sequences
A number of sequences are available which will allow the user to enter different modes during Start-up. Below is a table which outlines
these sequences. In each case, the user needs to hold the respective sequence buttons to activate that particular mode.
Mode
Sequence
Normal Operation
Start Switch (#12)
Service Mode
Stop Switch (#15) + Start Switch (#12)+ Top Left Switch (#9)
Copy USB H-Link Settings
Stop Switch (#15) + Start Switch (#12) + Lower Right Switch (#10)
Copy USB Graphics
Stop Switch (#15) + Start Switch (#12) + Lower Left Switch (#11)
Wireless Hetronic PC-Link
Stop Switch (#15): Active only for the initial 5s after Power Up
Shutdown
Stop Switch (#15) + Start Switch (#12)
Table 3. Start-Up Sequences