Under  the  Clean  Air  Act  local  authorities  may 
declare  the  whole  or  part  of  the  district  of  the 
authority to be a smoke control area. It is an of-
fence to emit smoke from a chimney of a buil-
ding,  from  a  furnace  or  from  any  fixed  boiler  if 
located  in  a  designated  smoke  control  area.  It 
is  also  an  offence  to  acquire  an”  unauthorized 
fuel” for use within a smoke control area unless 
it is used in an” exempt” appliance (” exempted” 
from  the  controls  which  generally  apply  in  the 
smoke control area).
In England appliances are exempted by publica-
tion on a list by the Secretary of State in accor-
dance  with  changes  made  to  sections  20  and 
21 of the Clean Air Act 1993 by section 15 of the 
Deregulation Act 2015. Similarly, in Scotland ap-
pliances are exempted by publication on a list by 

Scottish  Ministers  under  section  50  of  the  Re-
gulatory  Reform  (Scotland)  Act  2014.  In  Wales 
and  Northern  Ireland  these  are  authorized  by 
regulations made by Welsh Ministers and by the 
Department of the Environment respectively. 
Further  information  on  the  requirements  of  the 
Clean Air Act can be found here: 
https://www.gov.uk/smoke- control-area-rules 

Your  local  authority  is  responsible  for  imple-
menting the Clean Air Act 1993 including desig-
nation and supervision of smoke control areas 
and  you  can  contact  them  for  details  of  Clean 
Air Act requirements

The  Scan-Line  Solid  C  high  have  all  been  re-
commended as suitable for use in smoke con-
trol areas when burning dry wood logs.

3. Appendix A

The clean air act 1993 and smoke control areas.

Summary of Contents for SCAN-LINE SOLID C

Page 1: ...EADY 1 OPERAtING AND INStAllAtION INStRUCtIONS SCAN lINE SOlID C The scan line solid c is exempT for use in smoke conTrol areas when burning dry wood DANISh DESIGN DANISh QUAlItY DANISh PRODUCtION www...

Page 2: ...2...

Page 3: ...ta is a registered trademark of Heta A S 18 05 2022 0037 1514 Version 2 4 Printed in Denmark Subject to printing errors and changes Operating Instructions Contents Before installation 4 5 Accessory Pa...

Page 4: ...sted For inddbygning 1 BETJENINGS OG OPSTILLINGSVEJLEDNING SCAN LINE SOLID C DANSK DESIGN DANSK KVALITET DANSK PRODUKTION www heta dk DK 4 Operating Instruction manual Heta glove CHR list Standard V1...

Page 5: ...x 0023 2507 1 x 0023 2508 1 x 0023 2509 Heat shield 1 x 1022 0087 2 x 1022 0090 1 x 1022 0091 Adjustment device 2 x 1513 0151 1 right 1 left Graphite spray for lubrication Solid C high Top Concrete el...

Page 6: ...5032 0082 1 x 1522 0009 3 x 0008 1720 3 9x14 screw 1011 0275 1011 0276 1511 0032 4 x 0008 1720 3 9x14 5 x 0008 2301 M4x8 External air from below complete 1511 0033 90o Flue pipe 1 x 0050 0514 Solid H...

Page 7: ...ns The applian ces will only be considered as an exempt appli ance if this stop is in place 1 4 lighting the stove Place two pieces of wood on the bottom Stack kindling on top in layers with air betwe...

Page 8: ...ying in the bottom of the firebox Warning one must always use cation around the stove seen as it gets very warm during use in excess of 90 c children should avoid contact with the stove Setting up a f...

Page 9: ...blocka ges soot build up bird nests leaves etc Reduced draft can occur when The temperature difference is too small between smoke gasses and outdoor To short of a chimney The outside temperature is h...

Page 10: ...fit a damper in the flue gas pipe to regulate the draft When cleaning the chimney soot and other deposits may come to fall on the baffle plate remove and clean it In cases where the wood burns too qui...

Page 11: ...box C VI C Cleaning combustion air intake C C Cleaning of the firebox C VI C Checking switch gasket for door C S VI C S Checking changing gasket for glass C S VI C S Checking changing gasket for flue...

Page 12: ...on Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe if necessary The door or ash pan drawer...

Page 13: ...ore replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone removal sequence of stones Replace in reverse order Starting with Fig 8 13 1 3 4...

Page 14: ...cts from purchase date from Heta and a 3 months total warranty for seals vermiculite and glass from the date of sale from the dealer Claims concerning stoves older than 3 months will be assessed by ou...

Page 15: ...2 1 3 4 5 6 7 8 9 10 7 11 12 13 14 15 16 18 19 20 21 22 23 x 4 24 x 2 25 x 2 26 x2 27 x 2 28 x 2 29 x 2 31 32 33 34 30 35 36 37 17 15 1 21 Parts...

Page 16: ...pin 6x35 2 19 4013 0004 Start up air return spring 1 20 1513 0124 Closure mirrored 1 pos no name Qty 21 1513 0123 Closing System 1 22 1505 0084 Left hinged door 1 23 5013 0011 Rep set glass clips side...

Page 17: ...an be painted without priming Use a vapour perme able acrylic or latex paint possibly a cement based structure paint Installation Instructions Contents 2 Installation instructions 18 2 1 Distance requ...

Page 18: ...bustible material fou nd on the table on page 20 the data plate as well as drawings Pay special attention to the distance to flammable floor 330 mm which is also applicable although there is a steel g...

Page 19: ...n drops into the stove itself rather than collecting on the ex terior surface of the stove For connections to chimneys that are run through ceilings all national and local regulations regar ding dista...

Page 20: ...strations on this page has a thermal conductivity of max 0 36 W m K Solid C and Solid C high 1 Furniture safety distance front Min 1100 mm 2 At least 350 mm from top edge of concrete to flammable mate...

Page 21: ...21 3 3 min 4 1 2 9 Installation of the stove Solid C and Solid C high 2 3 x 4 7 5 2 x 1013 1006 6 8 5 3 3 5...

Page 22: ...22 9 10 11 x 2 12 x 2 15 16 13 x M6 x 25 0008x1807 1 1 2 2 3 2 3 13 x M6 x 8 0008 0035 Scan line Solid C 13 14 5 5...

Page 23: ...23 17 19 18 1 2 Scan line Solid C high 3 4 13 x M6 x 25 0008x1807 13 x M6 x 8 0008 0035 1 1 2 2 3 2 3...

Page 24: ...24 5 7 6 1 2 10 Rear flue outlet Accessory 5032 0082 Solid C and 5032 0092 Solid high 2 192 270 308 57 HM...

Page 25: ...21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015 Similarly in Scotland ap pliances are exempted by publication on a list by Scottish Ministers under section 50 of the Re gulator...

Page 26: ...4 5 6 26 5 x M4x8 4 Connecting external air supply from below 2 x4 1 3 x4...

Page 27: ...7 8 27 x4 2 1 x3 x3 90o 3 x3 5 Connecting external air supply from behind...

Page 28: ...28...

Page 29: ...29...

Page 30: ...30...

Page 31: ...ency NCV as received Useful efficiency at nominal heat output th nom 79 Useful efficiency at minimum heat output th min Auxiliary electricity consumption At nominal heat output elmax kW At minimum hea...

Page 32: ...32...

Reviews: