Heta Scan-Line 500D Operating Instructions Manual Download Page 1

Installation and Operating Instructions for Scanline 500 Stove Series 

Page 

1 of 10 

 

 

 
 
 
 
 

www.heta.dk

 

 

 

 

 

 

 

OP

ERA

TIN

IN

ST

RUCTIO

NS

 

Scan-Line 500D Series 

(500D, 510D, 520D, 530D) 

APPROVED FOR USE BY DEFRA IN SMOKE CONTROL AREAS 

WHEN BURNING DRY WOOD LOGS 

(when fitted with a permanent stops on primary and secondary air)

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

www.heta.dk

 

Summary of Contents for Scan-Line 500D

Page 1: ...Stove Series Page 1 of 10 www heta dk OPERATING INSTRUCTIONS Scan Line 500D Series 500D 510D 520D 530D APPROVED FOR USE BY DEFRA IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS when fitted with a p...

Page 2: ...ction fans operating in the same room as the wood burning stove can reduce the chimney draft which may have an adverse effect on stove combustion properties In addition this may cause smoke to be emit...

Page 3: ...orrect height at least 4 00 m above the stove and free of the roof ridge INSTRUCTIONS FOR USE First firing The stove has been treated with a heat resistant coating which hardens at a temperature of ap...

Page 4: ...dle at the back of the side panel The secondary airflow is completely open in top position fig 1 Shut off the secondary airflow gradually by lowering the handle The supply is completely shut off when...

Page 5: ...fire to build before refueling with larger pieces of wood and then adjust the sliders for optimum combustion Do not overload the firebox by loading above the tertiary air diffuser at the back of the f...

Page 6: ...intakes are closed completely This will prevent oxygen from being drawn into the stove and the viewing window and other parts will become covered with soot If this situation is combined with firing w...

Page 7: ...the casted shaking grate is it possible to clean the air channel for the start up airflow becoming covered in soot This soot can be easily and effectively removed by using proprietary stove glass cle...

Page 8: ...tallation and Operating Instructions for Scanline 500 Stove Series Page 8 of 10 Emptying the ash pan fig 5 8 Cleaning and replacing the fire bricks fig 9 12 Fig 5 Fig 6 Fig 7 Fig 8 Fig9 Fig10 Fig11 Fi...

Page 9: ...tion and Operating Instructions for Scanline 500 Stove Series Page 9 of 10 Changing to back smoke outlet fig 13 20 The stove is prepared for a fresh air intake Fig13 Fig14 Fig15 Fig16 Fig17 Fig18 Fig1...

Page 10: ...areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in No...