Hessaire 1300 CFM Use & Care Manual Download Page 2

 

MC18 Online Manual Eng Spa 081621

 

Inspection

 

After unpacking your cooler, carefully inspect for any dam-

age that may have occurred during transit.  Inspect for 

loose, missing or damaged parts.  

Note: wheels & hose 

adapter are located on top of cooler upon opening box.

 

Contents: Evaporative Cooler (1), Hose Adapter (1), Caster 

Wheels (4).

 

Visit Hessaire.com to request replacement parts if any of 

these items are missing.

 

1

  

Install Casters: Locking in front

 

2

  

Install Hose    

Adapter

 

Quick Start

 

Lay Cooler Down

 

Gather Casters, Push In To Install

 

2

 

Note: Media pads may have a slight odor upon initial start 

up but will go away with continued use.

 

3

  

Plug In To Power 

Supply

 

4

  

Fill Cooler

 

5

  

Turn On & Enjoy

 

A

 

B

 

C

 

(Not For     

Indoor Use)

 

Features

 

Control Functions For MC18

 

3

 

High Fan & Pump

 

Power Off

 

Low Fan & Pump

 

Low Fan Only

 

High Fan Only

 

Pump Only

 

Continuous Fill Option 

(not for indoor use)

 

Manual Fill Option

 

Convenient Carry 

Handle

 

Summary of Contents for 1300 CFM

Page 1: ...ure all power cords do not touch sharp edges hot sur faces or chemicals Immediately replace damaged parts Never leave unit unattended Continuous fill not to be used indoors or unattended Read and foll...

Page 2: ...replacement parts if any of these items are missing 1 Install Casters Locking in front 2 Install Hose Adapter Quick Start Lay Cooler Down Gather Casters Push In To Install 2 Note Media pads may have...

Page 3: ...oler won t turn on Ensure unit is plugged in and switched on Receptacle breaker may need to be reset If unit is equipped with a GFCI plug reset If unit has a timer ensure it is off May need new ON OFF...

Page 4: ...from misuse negligence alteration or lack of necessary maintenance Loss of time inconvenience use of product or other consequential damages due to defects Return transportation costs All return costs...

Page 5: ...es o productos qu micos Reemplace inmediatamente las piezas da adas Nunca deje la unidad desatendida El llenado continuo no debe usarse en interiores o sin vigilancia Lea y siga todas las instruccione...

Page 6: ...saire com para solicitar piezas de repuesto si falta alguno de estos elementos 1 Instale ruedas 2 Instale el adaptador de manguera no para uso en inte riors Inicio Coloque Instale ruedas 2 Nota las al...

Page 7: ...g rese de que la unidad est enchufada y encendida Es posible que sea necesario restablecer el disyuntor del recept culo Si la unidad est equipada con un enchufe GFCI rein cielo Si la unidad tiene un t...

Page 8: ...as o las reparaciones de enfriadores independiente mente de si el producto est en garant a o no Env os da ados Hessaire no se hace responsable de los env os da ados o la escasez que resulten del mal m...

Reviews: