-7-
1.4
Specifications
SENSOR
MECHANICAL/ELECTRICAL/OPERATIONAL
Scanning Method
Mechanical Rotation
Wavelength
905 nm
Channel
32
Laser Class
Class 1 Eye Safe
Instrument Range
0.05 to 120 m
Ingress Protection
IP6K7
Range Capability
80 m @10% reflectivity (Channels 9~24)
Dimensions
Height: 7
6.0 mm
50 m @10% (Channels 1~8,25~32)
Top/Bottom Diameter: 100.0 / 103.0
mm
Range Accuracy
±1 cm (typical)
Operating Voltage
DC 9 to 36 V
Range Precision
0.5 cm (typical)
Power Consumption
10 W (typical)
FOV (Horizontal)
360°
Operating Temperature
-20℃ to 65℃
Resolution (Horizontal)
0.09° (5 Hz)
Weight
0.8 kg
0.18° (10 Hz)
DATA I/O
0.36° (20 Hz)
Data Transmission
UDP/IP Ethernet (100 Mbps)
FOV (Vertical)
31° (-16° to +15°)
Data Outputs
Distance, Azimuth Angle, Intensity
Resolution (Vertical)
1°
Data Points Generated
Single Return: 640,000 points/sec
Frame Rate
5 Hz, 10 Hz, 20 Hz
Dual Return: 1,280,000 points/sec
Returns
Single Return (Strongest, Last)
Clock Source
GPS / PTP
Dual Return (Strongest and Last)
PTP Clock Accuracy
≤1 μs
CERTIFICATIONS
PTP Clock Drift
≤1 μs/s
Class 1 Laser Product
CE, FCC, FDA, IC, RCM,
EAC
NOTE Specifications are subject to change. Please refer to the latest version.
NOTE Range capability: 100 klux ambient intensity, PoD (probability of detection) > 90%, FAE (false alarm rate) < 10E-5.
NOTE Range accuracy and precision: may vary with range, temperature, and target reflectivity. The typical values are the average among
channels, measured outdoors within 0.5 ~ 70 m, under 30℃ ambient temperature, and with a target reflectivity of 50%.