51
7
Sensor Maintenance
■ Storage
The product has passed the high- and low-temperature storage tests in ISO 16750, in which the test temperature range is -40℃ to 85℃.
We recommend storing the product in a dry, well ventilated place, under room temperature (23±5°C) and a relative humidity of 30% to 70%.
Please check Section 1.4 (Specifications) for product IP rating, and avoid any ingress beyond that rating.
■ Transport
Package the product in shock-proof materials to avoid damage during transport.
■ Cleaning
Stains on the product's enclosure, such as dirt, fingerprints, and oil, can negatively affect point cloud data quality.
Please perform the following steps to remove the stains.
NOTE
· To avoid damaging the optical coating, DO NOT apply pressure when wiping the enclosure
· Only clean the stained area of the enclosure
· Check before using a lint-free wipe. If the wipe is stained, use another
1) Thoroughly wash your hands or wear a pair of powder-free PVC gloves
2) To remove dust, blow dry air onto the enclosure, or use a piece of lint-free wipe to lightly brush across the dusty area
To remove persistent stains, move on to the next step
(Continued on the next page)