-33-
4.1
Home
Spin Rate of the motor (revs per minute) = frame rate (Hz) * 60
GPS (PPS) Status
Lock
LiDAR's internal clock is in sync with GPS
Unlock
Not in sync
NMEA (GPRMC/GPGGA) Status
Lock
After receiving a valid NMEA message
Unlock
No valid NMEA message for over 2 seconds
PTP Status
Free Run
No PTP master is selected
Tracking
Slave is trying to sync with the selected PTP
Master, but the absolute offset is over 1 μs
Locked
Absolute offset between Slave and Master is < 1 μs
Frozen
(Holdover)
LiDAR has lost connection to the PTP master and is
attempting to recover it.
Meanwhile, LiDAR starts drifting from the previous
clock; when drifting out of specifications, it goes
back to the Free Run mode.
Device Log
Click to download a .JSON file containing the LiDAR's status,
device info, all configurable parameters, and upgrade log.