9
Menu navigation and adjustment values
28
9.7
Switching the boiler on and off (chimney sweeping function)
SWITCH-ON
SWITCH-OFF
Navigation:
Navigation:
Screen:
Screen:
By pressing the button:
By pressing the button:
the boiler will be switched on.
the boiler will be switched off.
the boiler will switch off, remains
off and the previous page will be
displayed.
the boiler remains on and the
previous page will be displayed.
Note:
Note:
The system can only be switched on if there are no
errors that prevent it from starting.
The boiler will switch to the operating condition “burn
out phase” (except “cold start” or “ready”). When
switching off during cold start, the cold start is ended
and then changes to the burnout phase. This
prevents impermissibly high amount of fuel in the
combustion chamber.
CHIMNEY SWEEPING FUNCTION
Navigation:
Screen:
If “chimney sweeping function” is
active, the remaining time can be
raised in 5 minutes steps by
pushing the
-button.
Raises
the
remaining
time
(chimney sweeping mode) by
5 minutes steps.
After pressing the chimney sweeping symbol, the
boiler can also be switched off.
Summary of Contents for pelletfire 20/20
Page 1: ...OPERATING INSTRUCTIONS Log wood pellet heating system pelletfire 20 40 ...
Page 90: ...15 Annex 90 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 91: ...Annex 15 91 Hydraulic recommendation 2 ...
Page 92: ...15 Annex 92 15 2 Solar module Program 1 ...
Page 93: ...Annex 15 93 Program 2 ...
Page 94: ...15 Annex 94 Program 3 ...
Page 95: ...Annex 15 95 Program 4 ...
Page 96: ...15 Annex 96 Program 5 ...
Page 97: ...Annex 15 97 Program 6 ...
Page 98: ...16 Notes 98 16 NOTES ...
Page 99: ...Notes 16 99 ...