29
Configuration menu
the option „OFF“ to deactivate automatic switching with
the handwheel.
• Confirm with the Boost button.
10.8 S
etting
offSet
temperature
(
t
of)
As the temperature is measured on the radiator, the tem-
perature distribution can vary throughout a room. To adjust
this, a temperature offset of ±3.5 °C can be set. If a nominal
temperature of e.g. 20 °C is set but the room presents with
only 18 °C,an offset of -2.0 °C needs to be set.
If you use the ETKF+ Radiator Thermostat in connec-
tion with a Wall The, the temperature will
be measured at the Wall The.
In the HERZ Room solution you can configure the set-
tings for the ETKF+ Radiator Thermostat via the Wall
The.
If you use the ETKF+ Radiator Thermostat in the HERZ
Radiator solution, proceed as follows:
• Press the Auto/Manu button longer than 3 seconds.
• Select the menu item „tOF“ with the handwheel and con-
firm with the Boost button.
• Turn the handwheel and set the desired offset tempera-
ture (max. ±3.5°C).
• Confirm with the Boost button.