HERZ
GmbH
16
BA HD240 V30 R24 10_2017 EU short.doc
4.
SILENCER HOUSING MOUNTING INSTRUCTIONS
The ‘FJET’ series was designed to provide maximum flexibility in
the positioning of the silencer housings to meet various
installation configurations.
The blower is supplied with the silencers configured as in Fig. 1
If this configuration needs to be modified, proceed as
follows:
1.
Identify the desired configuration (Fig.2, Fig.3, Fig.4).
2.
Disassembly of the silencer housing:
2.1 Remove the #906 screws.
2.2 Take away the #700 silencer from the unit along with the
#424 gasket.
3.
Disassembly of the #730 blind flange:
3.1 Remove the #909 screws, taking away the #730 flange
along with the #427 gasket.
Reassemble in reverse order-do not forget the #427 gaskets.
4.1
USING THE 90° MANIFOLD KIT TYPE CK
(accessory)
The 90° manifold can only be installed on the #162 cover ports
and as shown in the Figures below, there are multiple
configurations.
The 90° manifold kit type CK comes supplied with; 1 x manifold
1 x #427 gasket and x M8x25 UNI 5739 screws.
To mount the 90° manifold, proceed as follows:
1. Disassemble the silencer housing (see point 2)
2. Place the #427 gasket between the #162 cover and the 90°
manifold and seal with the M8x25 UNI 5739 screws.
Assemble the silencer housing in reverse order-do not forget the
#424 gaskets.