14
2-1-3 Setting the stop input logic
The machine is so designed that the logic of a stop input signal can be set to either
“Negative
logic” or “Positive logic.” Note that the resulting operation differs depending on whether the
Working hour is set to be used or not used.
Setting
Set value
Description
Negative logic
*0
See the table below.
Positive logic
1
See the table below.
* Default values
Setting
Terminal input
Working hour
Stop input logic
ON
OFF
Used
Negative
Stop
Operating
Positive
Operating
Stop
Not used
Negative
Operating
Stop
Positive
Stop
Operating
<How to set>
(1) When on the function settings screen, press the [3] key on the keyboard.
The currently set value appears after
the sub command “C3” is displayed for 0.75
seconds.
(2) As the value you want to set, input either [0] (Negative logic) or [1] (Positive logic).
<e.g.> To set the stop input logic to Negative logic, input [0]. The resulting display is as
follows:
(3) Press the [ENT] key to set the value you input. If you have inadvertently set a wrong
data, press the [CLR] key and re-input the correct data.
F
1
[Function settings screen]
C
3
The sub command is
displayed.
*
The set value appears.
0