21D-265C
58
Applied operation
7-2. Working setting A - Operation when
“No” for working hour setting is set(Without Tact
reserve function)
This article describes about the Working setting
“
A
”
.
When Working setting (M=?)is displayed as
“
A
”
in the Operating status screen, the
Function setting is carried out as stated in the following table.
Working
setting
With/Without of Tact reserve
function [5]
With/Without of working hour [6]
Tact
reservation
Cumulative
display
For use of Working hour
“
A
”
No
No
No
The Working setting
“
A
”
allows the planned quantity to be calculated without setting the
working hour while the signal being inputted from outside is regarded as
“Within
working hour
”.
The working hour registration and the working pattern selection are disabled. Since
working hour is not registered, there is no starting time and finishing time. Accordingly,
recalculating function by means of [CLR] key is not available.
The input terminal for
“Stop input” operation in the Working setting “1” - “3” is changed
into the operation for
“Operating input” in the Working setting ”A” - ”C”.
The
“During Stop” output terminal is also disabled.
The key function is basically same as the basic operation; however, the key functions
stated below are changed.
(For other portions, see the page 21 of Basic operation.)
Key
Command
Functions
[5]
Working hour
Disable
[6]
Working
hour
pattern
Disable
[CLR]
Clear
Clears the Actual, and allows the calculation of planned quantity
according to the tact from the present time.