21D-265C
45
Basic operation
6-11. Setting the Pre-scale
Key [8]
Set the pre-scale here. The pre-scale function includes the multiple number setting and
batch number setting. Once either [Multiple number] or [Batch number] is selected in the
Function settings, this function is enabled. If neither of [Multiple number] nor [Batch
number] is selected in the Function settings, this function is disabled, thus [8] key cannot
be selected.
Multiple number setting
・・・
It allows the multiplied content, which is set for actual
input/subtraction input, to go up/down.
Up/Down by means of [
▲
]/[
▼
] key allows increasing/decreasing one
by one point regardless of any pre-scale set values.
Batch number setting
・・・
Once the Batch number set for actual input/subtraction input is
reached, the numeric value goes up or down one by one point. The
actual input and subtraction input, which do not exceed the Batch number,
are memorized into this machine, however, if they are cleared, the
memorized contents will be erased.
Up/Down by means of [
▲
]/[
▼
] key allows increasing/decreasing one
by one point regardless of any pre-scale set values.
To carry out the Multiple number setting [Multiple number]:
①
Press [8] key.
②
Input the Multiple number to be set.
<e.g.>
To set
“120”, input [1] [2] and [0] in this order.
If you have inadvertently set a wrong data, press [CLR] key and input once again.
③
Here, pres [ENT] key to set the Multiple number.
*If you have inadvertently pressed a wrong numerals, press [CLR] key to get back to the
Step
①
.
*Also for the Batch number (Batch), take setting in the same manner as above.
※M.N:Multiple
number
B.N:Batch
number
{8}M.N
[*****]
Input
[
]
[
*
]present data
M.N: Multiple number
{8}M.N
[*****]
Input
[
120]
[
*
]present data