Basic operation
6-4. Setting the Tact Key [0]
Setting tact in seconds (the time required for production per product)
①
Press [0] key , and the tact setting screen appears.
②
Input the Tact (man-hours) of your interest in seconds within less than 5-digit.
The setting ranges vary with the tact precision (0.1sec/0.01sec) which was set in
operation setting.
0.1sec setting
→
0.1-9999.9sec
0.01sec setting
→
0.01-999.99sec
<e.g.>For 45.5sec, input [4][5] and [5] in this order.
③
Here, press [ENT] to set the tact.
*If you have inadvertently set a wrong data, you may press [CLR] key to get back to the
Step
①
.
Tact can be changed at anytime.
If tact is
“
0
”
, the machine does not compute any progress.
{0}Tact
[****.*]
Input
[
.
]
[
*
]present data
The screen is for tact precision (0.1)sec
{0}Tact
[****.*]
Input
[
45.5]