![HEROSE 05411 Operating Instructions Manual Download Page 28](http://html1.mh-extra.com/html/herose/05411/05411_operating-instructions-manual_2126790028.webp)
Operating instructions
22
Phone +49 4531 509-0
5
Assembly
5.1
Installation position
≤ DN150
With regard to the installation position, pay attention to the arrow showing the flow direction. When
mounting the check valve in a horizontal pipeline, a vertical position of the obturator is recommended
(cover facing upwards) or an inclination of up to 65° from the vertical.
DN200
With regard to the installation position, pay attention to the arrow showing the flow direction. When
mounting the check valve in a horizontal pipeline, a vertical position of the obturator is recommended
(cover facing upwards) or an inclination of up to 45° from the vertical.
5.2
Notices regarding the mounting
Use suitable tools.
Allen keys of sizes 6, 8, 10, 14, 19;
Open-ended spanners;
Torque wrench;
TIG welding machine;
Oxy-fuel welding machine;
Clean tools before the mounting.
Use suitable transport and lifting equipment for the mounting.
Open the packaging only directly before the mounting. Freedom from oil and grease for oxygen
(O
2
).
Check valves for oxygen are permanently marked with “O
2
”.
Only install the check valve if the maximum operating pressure and operating conditions of the
plant correspond to the valving marking on the check valve.
Remove protective caps or covers before mounting.
Check the check valve for dirt and damage.
DO NOT install damaged or dirty check valves.
Remove dirt and residues from the pipeline and check valve in order to prevent leaks.
Avoid damaging the connections.
The sealing surfaces must remain clean and intact.
Seal the check valve with suitable seals.
No sealant (sealing tape, liquid sealing tape) may enter the check valves.
Respect the suitability for use with O
2
.
Connect pipelines in a force-free and torque-free manner.
Stress-free mounting.
In order to ensure trouble-free operation, no impermissible static, thermal or dynamic stresses
may be transmitted to the check valve. Observe reaction forces.
Temperature-dependent changes in length in the pipework system must be compensated with
expansion joints.
The check valve is supported by the pipework system.
The check valve must be protected against dirt and damage during construction work.
Check the leak-tightness.
Summary of Contents for 05411
Page 2: ......
Page 6: ......
Page 20: ...Betriebsanleitung 14 Telefon 49 4531 509 0 ...
Page 34: ...Operating instructions 28 Phone 49 4531 509 0 ...
Page 48: ...Instrucciones de servicio 42 Teléfono 49 4531 509 0 ...
Page 62: ...Notice d utilisation 56 Téléphone 49 4531 509 0 ...
Page 76: ...Руководство по эксплуатации 70 Телефон 49 4531 509 0 ...
Page 90: ...HEROSE GMBH ARMATUREN UND METALLE IV Phone 49 4531 509 0 Notizen Note Apunte Note заме тка 杂记 ...
Page 91: ...HEROSE GMBH ARMATUREN UND METALLE herose com V Notizen Note Apunte Note заме тка 杂记 ...