EN
– Translation of the original user manual - 2.0 | 2019
66
FAULTS
8
8.1
DEFECTIVE PHOTOCELL OR SAFETY EDGE
If a photocell or safety device is defective, the gate can only be opened and closed
using the hold-to-run switch. In this case, consult a qualified technician.
See chapter “SERVICE / MAINTENANCE”
8.2
PARAMETERS REFERENCE/ERROR NUMBERS
The possible entries in the log system described above for events and/or errors
are listed in the table below:
Reference/
Error no.
Text
Meaning
25
Fixed.StripOPEN Fixed safety contact strip OPEN was activated
(a ‘0’ is stored immediately after the text if the
motor was not active)
26
Fixed.StripCLOS
E
Fixed safety contact strip CLOSE was activated
(a ‘0’ is stored immediately after the text if the
motor was not active)
27
Acc.StripOPEN Accompanying safety contact strip OPEN was
activated
(a ‘0’ is stored immediately after the text if the
motor was not active)
28
Acc.StripCLOSE Accompanying safety contact strip CLOSE was
activated (a ‘0’ is stored immediately after the
text if the motor was not active)
40
Light barrier
The light barrier was activated during the CLOSE
movement
86
Number of
reversals
The maximum number of reversals for a
movement direction (without reaching the limit
position) was reached
130
Scstrip
OPENtsterr
Error in test result for the fixed safety contact
strip OPEN was detected
131
Scstrip CLOSE
tsterr
Error in test result for the fixed safety contact
strip CLOSE was detected
Summary of Contents for HMD Basic
Page 2: ...EN Translation of the original user manual 2 0 2019 2...
Page 75: ...EN Translation of the original user manual 2 0 2019 75 Appendix A Declarations Dop DoC...
Page 76: ...EN Translation of the original user manual 2 0 2019 76...
Page 77: ...EN Translation of the original user manual 2 0 2019 77 Appendix B ELECTRIC DIAGRAM HMD24...
Page 78: ...EN Translation of the original user manual 2 0 2019 78...
Page 79: ...EN Translation of the original user manual 2 0 2019 79...
Page 80: ...EN Translation of the original user manual 2 0 2019 80...
Page 81: ...EN Translation of the original user manual 2 0 2019 81...
Page 82: ...EN Translation of the original user manual 2 0 2019 82...
Page 83: ...EN Translation of the original user manual 2 0 2019 83...
Page 84: ...EN Translation of the original user manual 2 0 2019 84...
Page 85: ...EN Translation of the original user manual 2 0 2019 85...
Page 86: ...EN Translation of the original user manual 2 0 2019 86...
Page 87: ...EN Translation of the original user manual 2 0 2019 87...
Page 88: ...Local supplier stamp Lokal terf rs ljare st mpel...