Heraeus 66041213 Operating Instructions Manual Download Page 1

Heracast EC

GB

 

Operating instructions 

 

Heracast EC

Dateiname:

  W10095_66044668_02_BA_Heracast_EC_GB_V4_X3

SAP-Nr: Version

66044668 02

HK-Toolbox-Nr:

W10095

Format: Falzmaß:

420 x 280 mm 

210 x 280 mm

Projektmanager:

Michael Helken

HKG-Version:

V4, 3.AK

Datum 

HKG Freigabe am 

01.10.2013 07.10.2013

HKG-Layout 

66044668_02_BA Heracast EC_GB

 

EURO / Pantone   

Sonderfarben

 

Druckverfahren: 

Digitaldruck

 

 

varnish DieCut var.Data

https://stomdevice.ru -

стоматологическое и зуботехническое оборудование с доставкой по России и СНГ

Summary of Contents for 66041213

Page 1: ...n 66044668 02 HK Toolbox Nr W10095 Format Falzma 420 x 280 mm 210 x 280 mm Projektmanager Michael Helken HKG Version V4 3 AK Datum HKG Freigabe am 01 10 2013 07 10 2013 HKG Layout 66044668_02_BA Herac...

Page 2: ...https stomdevice ru...

Page 3: ...w open chamber 10 5 3 Partial view cooling water 11 5 4 Partial view inlet and power connections 12 6 Location and installation 12 6 1 Transport 12 6 2 Unpacking 12 6 3 Set up 13 6 4 Mains connection...

Page 4: ...re 23 daily 23 weekly or after 100 castings 23 annually or after 3 000 castings 23 after 10 000 casting or after 3 years 23 11 2 Tests 23 11 3 Maintenance 24 11 4 Disposal 24 11 5 Disposal of old equi...

Page 5: ...Type of machine Serial No Induction vacuum pressure casting machine Heracast EC 2010 01 0001 ff 1 3 EU Statement of conformity Herewith we Heraeus Kulzer GmbH Gr ner Weg 11 63450 Hanau Germany confirm...

Page 6: ...operator must ensure the statutory obligations are observed and implemented at the working place i e he must train his personnel and comply with industrial safety legislation and any other regulation...

Page 7: ...different parts holds unknown risks and must be avoided at any rate Proper function and safety of the unit are only guaranteed if the required tests maintenance and repair work have been performed by...

Page 8: ...lids The unit must not be used to heat up food 4 Scope of delivery consumables set Check that all components are in perfect condition on delivery of the machine If you wish to make a complaint contact...

Page 9: ...ast EC 9 GB 5 Structure and function 5 1 Control and display elements 1 2 3 4 1 Viewing glass casting chamber 2 Graphic display with control elements 3 Locking lever casting chamber 4 Filter cover air...

Page 10: ...sting chamber 6 Ceramic crucible 7 Shielding plate 8 Adjustable casting ring holder 9 Locking lever casting chamber 10 Collecting plate 11 Screw for adjustable casting ring holder 12 Clamping device f...

Page 11: ...Operating instructions Heracast EC 11 GB 5 3 Partial view cooling water 16 15 15 Side trap door with viewing glass for cooling water level 16 Carrying handle https stomdevice ru...

Page 12: ...s connection 6 Location and installation 6 1 Transport Carefully transport the unit horizontally to prevent the pump oil from leaking and damaging the unit Packings and units must not be stacked Shock...

Page 13: ...he circuit of the receiver 6 4 Mains connection Mains 200 230 V AC 1 P N PE 50 60 Hz connect to mains in accordance with VDE specifications and local power supply specifications with flexible mains co...

Page 14: ...lated If several units are to be placed in one room special ventilation measures may be required e g zone ventilation 7 Operations The following pages are to provide basic information and hints which...

Page 15: ...igh Allow to cool down WD Cooling OSC Temp 10 C 10 C 1 sec Oscillator temperature outlet too low WE Cooling WTR Temp 55 C 55 C 1 sec Cooling liquid temperature inlet too high Allow to cool down WF Coo...

Page 16: ...ec Inside air temperature too high EH Cooling AIR Temp 5 C 5 C 1 sec Inside air temperature too low EI Induction PDC 1900 W 1900 W 1 sec Generator power output too high EJ Induction Energy control Aft...

Page 17: ...p is automatically activated and creates a vacuum inside the chamber From a vacuum level of 250 mbar an acoustic signal is heard and the speaker icon is animated As long as the signal is heard you may...

Page 18: ...is inverted 28 Variable menu bar options can be selected using the push button 29 Push button for menu bar 30 Status displays 8 1 1 Icons in the status display Chamber open Indicates that the casting...

Page 19: ...change the default value anytime by turning the turning knob to the left or to the right Now close the chamber and start the melting process by pushing the key under the START menu item The chamber w...

Page 20: ...content can result in degassing or in damage to the alloy We recommend to use our graphite free phosphate bonded investment materials 9 3 Premelting In order to obtain uniform casting conditions all a...

Page 21: ...s sometimes omitted completely and premelt and main melt are carried out in a single working step with the ring being placed in see paragraph 10 4 Titanium and aluminium containing alloys The sprues a...

Page 22: ...ediately Main melt 100 power Observe delay time after the shadow see paragraph 13 Recommendations for casting Then press CAST key to start manual casting NOTE The NPM ceramic crucibles are exclusively...

Page 23: ...ting plate below the inductor the chamber the sliding rails and the washer when the unit is cold extract or clean with compressed air In case of moist compressed air empty the water extractor of the o...

Page 24: ...reduce both the volume of waste for disposal and the inclusion in waste of harmful substances from electrical and electronic equipment Consequently corresponding products from Heraeus Kulzer GmbH wil...

Page 25: ...to 40 C Relative humidity 80 to 31 C 50 at 40 C Installation altitude up to 2000 m above sea level Overvoltage category II Level of contamination 2 Protection class 1 Protection type IP 20 Duty cycle...

Page 26: ...ite insert 70 10 sec Mainbond A OG Bio Maingold TK 990 C Graphite insert 70 10 sec Mainbond EH 1010 C Graphite insert 70 10 sec Mainbond SUN 1030 C Graphite insert 70 10 sec Bio Maingold I Bio Heranor...

Page 27: ...0 sec Bio SupraCeram 1175 C Graphite insert 100 10 sec Recommendation To enable clear analysis of the melting process add a melting powder pellet small after premelting Pd based alloys and Gold Pd all...

Page 28: ...Observe melt after splitting up of the oxide layer interrupt premelt with STOP button Observe melt depending on alloy type interrupt premelt with STOP button Open casting chamber and add melting powde...

Page 29: ...ax 39 022 10 09 42 83 Japan Japan Heraeus Kulzer Japan Co Ltd 2F TSK Bldg 8 13 Hongo 4 chome Bunkyo ku 113 0033 Tokyo Tel Phone 81 358 03 21 53 Fax 81 358 03 21 50 Mexiko Mexico Heraeus Kulzer Mexico...

Page 30: ...10 03 First release 2011 04 Editorial modifications technical data Complete Service agents and update contacts in the countries 2013 10 Text editing Adding paragraph 7 4 Subject to modifications Dated...

Page 31: ...https stomdevice ru...

Page 32: ...W10095 GB 66044668 02 2013 10 Heraeus Kulzer GmbH Gr ner Weg 11 63450 Hanau Germany Telefon 49 61 81 35 58 94 Telefax 49 61 81 35 59 93 https stomdevice ru...

Reviews: