6.1.6.3 Seal
This is the time that the sealing wire and/or the cut-off wire are heated. The longer the time, the
more heat is transferred to the bag.
1.
Use the Cursor key to scroll to the parameter Seal.
The LED in front of the selected function will light up.
2.
Press the – / STOP button and the + / VACUUM STOP button to adjust the value.
The – / STOP button and the + / VACUUM STOP button must be pressed and held for several
seconds to adjust the value. This prevents the accidental changing of settings.
3.
Press the Cursor key to activate the new parameter.
6.1.6.4 External Vacuum (optional)
The External Vacuum function allows special food containers to be vacuum extracted outside of
the machine.
Check in advance whether the relevant gastronorm container can withstand and hold a vacuum.
To select the External Vacuum option, follow the steps below.
1.
Select the External Vacuum programme.
a.
Press the Pump Cleaning Program button.
The display will show "C".
b.
Press the Cursor key.
The display will show "E".
2.
Connect the external vacuum hose to the machine by placing the adapter over the suction
inlet (1) in the vacuum chamber.
3.
Connect the external vacuum hose to the packaging.
a.
Connect the adapter (3) of the external vacuum hose to the valve of the food container.
b.
Slide the sliding valve (2) towards the hose (closed position).
Figure 4: External Vacuum Adapter Set (1-PCS)
4.
Press the + / VACUUM STOP button to start the vacuum cycle.
The food container will be vacuum extracted.
5.
Slide the sliding valve of the adapter towards the gastronorm container (open position) and
remove the external vacuum hose from the food container.
Operation 22