Troubleshooting 59
8 Troubleshooting
The tables below show the possible malfunctions and the corresponding causes as well as the
steps to be taken.
Malfunction
Activity
More information
Control panel does not
illuminate.
•
Connect the machine to the
power supply.
•
Check the machine/circuit
breaker.
Electrical Installation on page
20.
The control panel is on, but
there is no activity after closing
the lid.
•
Check or adjust the switch of
the lid.
Contact your supplier.
Insufficient end vacuum.
•
Check the vacuum settings
of the program and adjust
them.
•
Make sure that the
extraction opening is not
covered.
•
Check the oil level in the
pump.
•
Check/replace the oil
exhaust filter.
•
Check/replace the lid
gasket.
Changing the Program Settings
on page 33.
Replacing the Oil Exhaust Filter
on page 53.
Replacing the Lid Gasket on
page 57.
Vacuum process is slow.
•
Make sure that the
extraction opening is not
covered.
•
Check the oil level in the
pump.
•
Check/replace the oil
exhaust filter.
Replacing the Oil Exhaust Filter
on page 53.
Vacuum bag is not sealed
correctly.
•
Check the seal settings
of the program and adjust
them.
•
Check/replace the Teflon
tape and the sealing wires.
•
Check/replace the silicone
rubber of the silicone
holders.
Changing the Program Settings
on page 33.
Replacing the Sealing Wire on
page 54.
Replacing the Silicone Rubber
of the Silicone Holders on page
56.