Henkel, Inc.
P.O. Box 1322
Hammond, LA
70404
(985) 345-2171
www.keenovens.com
Page 1: ...Henkel Inc P O Box 1322 Hammond LA 70404 985 345 2171 www keenovens com...
Page 2: ...ritical to have continuous operation of this unit we suggest having the following spare parts on hand Heating Element Power Cord Thermostat General Information The K 15R is a portable oven designed fo...
Page 3: ...specified on the name plate of the unit Check outlet to ensure proper grounding of the electrical cable Have a licensed electrician check the A C power outlet if you are not sure Use this unit for its...
Page 4: ...field When attaching the plug to the power cord be sure the plug is an approved component and is rated for the proper voltage and amperage All units meet electrical code requirements when used with a...
Page 5: ...from old element and remove element 5 Install new element and attach leads 6 Replace insulation and bottom cover 7 See wiring diagram CHANGING THE THERMOSTAT MODEL K 15R 1 Disconnect from the power s...
Page 6: ...03 5 1 Thermostat 301024 6 1 Rod Lifter Assembly 100107 7 1 Strain Relief 301043 8 Neon Pilot Light 301085 Note 301021 240V 400W used in the K 15 Oven produces 100W output Please state model number an...
Page 7: ...max 240 F 50 Not required 700 F 100 two hours CONTACT YOUR ELECTRODE MANUFACTURER FOR SPECIFIC INFORMATION INVOLVING CRITICAL OPERATIONS Electrode coating should not be exposed to the rebaking tempera...