12
•
Loosen the reservoir knobs and remove the lid.
•
Check that there is no condensed moisture at the bottle or the
sensor surface.
•
Place the bottle in the bottle holder (see the right figure).
•
Check that the product bottle inserted in the bottle holder is
pressed again the level sensor.
•
Insert the product feedline into the bottle and put on the lid.
•
Uniformly tighten the reservoir knobs by hand.
•
Set the depressurizing valve (12) to
“ON”
position (pressurize).
5
Operation
5.1 Function of the Control Panel:
Switch (4):
Switching different mode as below cycle.
Press the ‘Mode’ button to scroll through configuration selections:
Run: Auto
>
Run: Manual
>
Run: Continuous > Set: Time (Auto) > Set: Delay (Auto)
> Set: Output > Set: Low Level > Set: Lock-Out
Detailed description of each function is described in sections 5.4 to 5.11
Switch (7):
Set the data in all “SET: XXXX” mode.
Switch (5):
For parameter digit position change. Digit position will move 1 digit to the right.
Switch (8):
For numbering change. Change
from “0 –
9” or switching each option by each press.