10
-
Use flexible pneumatic hoses and Loctite supplied product feedlines to prevent
unnecessary loads on the fitting and to ensure compatibility.
-
Keep all fittings tight.
-
No direct sunlight; no UV light.
-
No condensing humidity.
-
Avoid direct connect with water.
4.2 Connecting the Unit
-
Use only the cable and hose sets supplied.
-
Connect Air pressure supply to pneumatic connection (22).
-
Connect power adapter with cord supplied to 24VDC power in connection (23).
-
For manual operation, plug the footswitch into the required 9 pin D-sub connector
marked XS1 (see section 5.2), located on the rear panel.
-
Insert feedline through the reservoir lid to the dimension shown below. Alternatively
use the reference line shown on the housing to set the feedline length. Cut the end
of the feedline at an angle as shown below.
-
Connect dispensing valve(s).