Warranty

 

 

Henkel expressly warrants that all products referred to in this Instruction Manual for Loctite

®

 

EQ RC32 Automatic Reservior SP 

(hereafter called “Products”) shall be free from defects in 

materials and workmanship. Liability for Henkel shall be limited, as its option, to replacing 

those Products which are shown to be defective in either materials or workmanship or to 

credit the purchaser the amount of the purchase price thereof (plus freight and insurance 

charges paid therefor by the user). The p

urchaser’s sole and exclusive remedy for breach of 

warranty shall be such replacement or credit.

 

 

A claim of defect in materials or workmanship in any Products shall be allowed only when it 

is submitted in writing within one month after discovery of the defect or after the time the 

defect should reasonably have been discovered and in any event, within (12) months after 

the delivery of the Products to the purchaser.  This warranty does not apply to perishable 

items, such as fuses, filters, lights, etc.. No such claim shall be allowed in respect of products 

which have been neglected or improperly stored, transported, handled, installed, connected, 

operated, used or maintained. In the event of unauthorized modification of the Products 

including, where products, parts or attachments for use in connection with the Products are 

available from Henkel, the use of products, parts or attachments which are not manufactured 

by Henkel, no claim shall be allowed. 

 

No Products shall be returned to Henkel for any reason without  prior written approval from 

Henkel. Products shall be returned freight prepaid, in accordance with instructions from 

Henkel. 

 

NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED, 

MISUSED, NEGLECTED, OR DAMAGED BY ACCIDENT.   

 

EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION, HENKEL MAKES 

NO WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO 

THE PRODUCTS. 

 

ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND 

OTHER WARRANTIES OF WHATEVER KIND (INCLUDING AGAINST PATENT OR 

TRADEMARK INFRINGEMENT) ARE HEREBY DISCLAIMED BY HENKEL AND WAIVED BY 

THE PURCHASER. 

 

Summary of Contents for 2814023

Page 1: ...1 EQ RC32 Automatic Reservoir SP IDH 2814023 Operating Manual...

Page 2: ...ion 5 2 2 Control Panel Front Back of controller 6 3 Technical Data 7 4 Installation 8 4 1 Environmental and Operating Conditions 8 4 2 Connecting the Unit 8 4 3 Filling and Refilling the Product Rese...

Page 3: ...are not observed the manufacturer can assume no responsibility Do not expose the connecting cable to heat oil or sharp edges Make sure the Unit stands stable and secure Use only original equipment re...

Page 4: ...oint product level sensor for process controls Integrated solenoid vent valve 1 6 Field of Application Intended use The Loctite EQ RC32 Automatic Reservoir SP is equipped with a single point low level...

Page 5: ...n connected to a controller 97102 97152 or RC15 the automatic reservoir is automatically pressurized when the controller is switched on and automatically depressurized when the controller is switched...

Page 6: ...ressure ON OFF Switch 2 Tank Pressure Gauge 3 Valve Pressure Relief 4 Reservoir Feedline Fitting 5 Reservoir Locking Knob x 3 6 Reservoir Lid 7 Pneumatic Connection P in 8 Low Level connector XS2 9 Lo...

Page 7: ...bs 4 8 8 Internal control voltages 24VDC Pneumatic Supply Clean dry air not to exceed 116 psi 8bar and filtered with a maximum of 10 micron Pneumatic hose size External dia 6mm Operating Temperature 1...

Page 8: ...nt unnecessary loads on the fitting and to ensure compatibility Keep all fitting tight No direct sunlight no UV light No condensing humidity Avoid direct contact with water 4 2 Connecting the Unit Use...

Page 9: ...d safety devices would become clogged and therefore ineffective Warning Before loosening the reservoir locking knobs 6 the EQ RC32 Automatic Reservoir must be depressurized pressure free When dispensi...

Page 10: ...ighten the reservoir knobs by hand Set the depressurizing valve 1 to ON position pressurize On the controller 97102 switch the reservoir to active with the button On the controller 97152 or RC15 switc...

Page 11: ...to the product feed line 5 Insert the product bottle For small bottles use the bottle holder For 250ml product bottle pay attention to ensure the bottle is aligned with the level sensor 6 Check that t...

Page 12: ...pneumatic supply from the unit Clean the product hose and dispensing valve Recommended maximum idle times for different products are shown below Adhesive Maximum idle time for dispensing Systems Anaer...

Page 13: ...spensing valve not correctly connected or defective Check the dispensing valve see instruction manual for dispensing valve Product reservoir pressure is too high Lower pressure longer dispensing time...

Page 14: ...he feedline hose Remove the product bottle and insert a container with approx 0 5 liter of cleaning agent Put on the reservoir lid 6 and uniformly tighten the reservoir locking knobs 5 Operate the dis...

Page 15: ...bing 360636 2 Tank Cord 2 m 147521 3 inch O D Black PE Teflon Lined feedline Tubing 33 feet length 142646 4 Reservoir Lid O ring 478505 5 Pressure Safety Relief Valve 360462 6 Anti Bubbler Kit 2 Adapt...

Page 16: ...rishable items such as fuses filters lights etc No such claim shall be allowed in respect of products which have been neglected or improperly stored transported handled installed connected operated us...

Page 17: ...T POSSIBLE UNDER APPLICABLE LAWS HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF OR OTHERWISE IN CONNECTION WI...

Page 18: ...Haw Par Technocentre SINGAPORE 149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seou...