background image

18

(1)

How to Enable/Disable Alarm under Telephone Line Short

Circuit or Open Circuit

Enter

6#

to enable alarm under telephone line short circuit

or open circuit

Enter

7#

to disable alarm under telephone line short circuit or

open circuit

It is recommended to enable alarm under telephone line short circuit

or open circuit. Under telephone line short circuit or open circuit, the

receiving host will give out urgent “Beep··Beep··” sound prompt.

(2) How to Modify User Password

Enter

9#AAAAAA#AAAAAA#

to change the old user password

into a new one.

“AAAAAA” is a new user password. Once user password is modified,

the old password will be automatically invalid. To enter into set-up

mode again, users should enter the new password.

It is recommended that users should change password timely and

take good care of password. If users have forgotten password, users

shall contact the distributor to ask for help.

(3)

(3)

(3)

(3) How

How

How

How to

to

to

to Set

Set

Set

Set Informed

Informed

Informed

Informed Telephone

Telephone

Telephone

Telephone Numbers

Numbers

Numbers

Numbers

Enter

11#BBBBBB#

to set the first group of informed

telephone numbers

Enter

12#BBBBBB#

to set the second group of informed

telephone numbers

Enter

13#BBBBBB#

to set the third group of informed

telephone numbers

Enter

14#BBBBBB#

to set the fourth group of informed

telephone numbers

Enter

15#BBBBBB#

to set the fifth group of informed

telephone numbers

Enter

16#BBBBBB#

to set the sixth group of informed

Summary of Contents for HB-2020 Series

Page 1: ...ontal Alarm Alarm Alarm Alarm Host Host Host Host User User User User Manual Manual Manual Manual A C Ningbo Ningbo Ningbo Ningbo Hengbo Hengbo Hengbo Hengbo Telecommunication Telecommunication Telecommunication Telecommunication Co ltd Co ltd Co ltd Co ltd ...

Page 2: ...n Functions and Characteristics 3 IV Name and Usage of Main Parts 4 V Interface Performance and System Connection 6 VI System Installation 6 VII Operating Instructions 7 VIII How toAdd Remove Wireless Detectors 15 IX Main Technical Specifications 16 X Packing List 16 XI List of Optional Parts 16 XII Simple Failure Recovery 17 ...

Page 3: ...sitivity easy operation powerful functions and stable performance HB 2020C wireless receiving host adopts secondary frequency conversion processing technology and adopts 8 bit single chip as control core It has advantages of high receiving sensitivity easy operation powerful functions and stable performance Besides it can automatically dial pre set telephone numbers and also has the function to se...

Page 4: ...y perform test so as to identify and debug failures in time III III III III Main Main Main Main Functions Functions Functions Functions and and and and Characteristics Characteristics Characteristics Characteristics 1 1 1 1 Function Function Function Function Introduction Introduction Introduction Introduction of of of of HB 2020 A HB 2020 A HB 2020 A HB 2020 A Wireless Wireless Wireless Wireless ...

Page 5: ...ss Wireless Wireless Receiving Receiving Receiving Receiving Host Host Host Host Based on HB 2020A host HB 2020A host increases functions as follows It can automatically dial six groups of pre set telephone numbers and two groups of pre set telephone numbers provided by ADEMCO CID Centre when alarming The pre set telephone numbers can be dialed 3 9 times It rushes to inform you alarm message by cu...

Page 6: ... the same time to stop dialing pre set telephone numbers When entering into setup mode press this key to exit When telephone line short circuit or cut off alarm function occurs press this key to stop this function or press this key again or reset power off the host to reactivate this function Time Display It is usually used to show time through a flashing second lamp When alarm occurs it is used t...

Page 7: ...slightly slightly slightly slightly flashes flashes flashes flashes Schematic Schematic Schematic Schematic Diagram Diagram Diagram Diagram of of of of Rear Rear Rear Rear Panel Panel Panel Panel Output Interface It is provided with a group of normally opened relay output a group of normally closed relay output and a group of uncontrolled DC 12V 300mAoutput Normally Opened Closed Relay Output Inte...

Page 8: ...h AC power Phone Set up Hold down the Phone Set up key for 2 5s to switch to the programmable device of dialling module Please refer to relevant parts in Operating Instructions Section for specific operations Fuse socket AC power fuse is equipped with AC250V 0 1A fuse tube AC Power Line This host adopts 220V 50HZ AC power supply Internal phone Jack It is connected with a user telephone External wi...

Page 9: ...e products shall be determined according to the effective defense zone of defense products and site conditions The defense products shall be installed in hidden locations as much as possible which must be in compliance with defense requirements The type of defense zones in each location should be labeled on the orientation drawing The orientation drawing should be archived for system maintenance 2...

Page 10: ...en out every second which means an alarm occurs when telephone line is cut off 2 2 2 2 How How How How to to to to Program Program Program Program HB 2020 HB 2020 HB 2020 HB 2020 Wireless Wireless Wireless Wireless Receiving Receiving Receiving Receiving Host Host Host Host After the host is powered on the screen of the wireless receiving host will show 12 00 00 through a lit second lamp and the l...

Page 11: ... The first group of automatic power on time setup mode and display the following information Hour Press Minute Press Function 2 key to set hour key to set minute Set the first group of power on time In this mode press or key to adjust the first group of automatic power on time After setup is completed press the Reset key to exit setup mode or press the Function key to set The first group of automa...

Page 12: ... How to to to to Set Set Set Set the the the the Second Second Second Second Group Group Group Group of of of ofAutomatic Automatic Automatic Automatic Power Power Power Power On On On On Time Time Time Time Press the Function key to enter into The second group of automatic power on time setup mode and display the following information Hour Press Minute Press Function 4 key to set hour key to set ...

Page 13: ... out time is 18 00 p m the power on power off time of the wireless receiving host should be set as follows The first group of power on time is 12 00 noon while the first group of power off time is 14 00 p m The second group of power on time is 18 00 p m the second group of power off time is 8 00 a m It is recommended to reserve some time for employees to check in ahead of schedule and stop off aft...

Page 14: ...rtain defense zone all defense zones will be automatically unbypassed It is recommended to apply this function when any failure occurs in defense zones Once the failure is recovered the host shall be set in bypass mode in time so as not to avoid loss of any alarm information in defense zones To prevent user from forgetting to restore the bypass zone the host will automatically reset all zone to or...

Page 15: ...nction key to enter into Alarm Sound and Alarm Sound Volume setup mode and display the following information Press to set Press to set Function 8 Alarm Sound Alarm Sound Volume Set Alarm Sound Function 8 serves to set alarm sound and alarm sound volume Press to set alarm sound and press to set alarm sound volume This host provides three types of alarm sounds 01 is 120 ambulance warning sound 02 is...

Page 16: ...A Manual Power Off Hold down key for 5 seconds to display the following information Figure B Manual Power On In manual power off mode as shown in Figure B hold down key used to set hour for 5 seconds and the host gives out a short Beep sound and at the same time second display zone of the host displays second or which means the host has returned to normal power on mode as shown in Figure A Note Us...

Page 17: ...amming set up through telephone handset Programming Programming Programming Programming Operation Operation Operation Operation How How How How to to to to Enter Enter Enter Enter into into into into Set up Set up Set up Set up Mode Mode Mode Mode Make sure to well connect the receiving host and to connect the telephone to the receiving host according to Interface Performance and System Connection...

Page 18: ... up switch within 20 seconds When telephone line connection is completed the wireless receiving host gives out urgent beep beep sound prompt If the telephone extension socket and telephone socket are wrongly connected because telephone line is cut off this sound prompt often occurs To avoid this problem please make sure telephone line is well connected and then set the host again In set up mode if...

Page 19: ...utomatically invalid To enter into set up mode again users should enter the new password It is recommended that users should change password timely and take good care of password If users have forgotten password users shall contact the distributor to ask for help 3 3 3 3 How How How How to to to to Set Set Set Set Informed Informed Informed Informed Telephone Telephone Telephone Telephone Numbers ...

Page 20: ...To change any group of telephone numbers users can directly enter new password or delete old password and then enter new password 4 4 4 4 How How How How to to to to Pre set Pre set Pre set Pre setTelephone Telephone Telephone Telephone Numbers Numbers Numbers Numbers of of of of ADENCO ADENCO ADENCO ADENCO CID CID CID CID Centre Centre Centre Centre Enter 17 Telephone Numbers of ADENCO CID Centre...

Page 21: ...ter 6 6 6 6 How How How How to to to to Set Set Set Set Dialling Dialling Dialling Dialling Times Times Times Times of of of of Informed Informed Informed Informed Telephone Telephone Telephone Telephone Numbers Numbers Numbers Numbers Enter 2 dialling times to set dialling times of informed telephone numbers The dialling times shall be set to 3 9 Note The dialling times of informed telephone numb...

Page 22: ...lephone handset otherwise users shall input relevant commands again Note If users enter 2 to disable alarm after receiving alarm information the wireless receiving host will stop dialing other groups of informed telephone numbers If users do not perform any operation after receiving alarm information the wireless receiving host will continue dialing one initues until other groups of informed telep...

Page 23: ...nu 11 code learning flickering display Display code learning status ˉˉ overline means code learning has been completed middle line means code is being added or removed Display zone number Press key to select zone number After determining the zone press the Function key and the host will give out a beep sound prompt and at the same time the screen displays 00 11 and 11 stops flashing which means th...

Page 24: ...reless detectors in power off mode but it still responds to operations of emergency button on remote control Emergency Zone It is also called 24 hour defense zone As long as the host is under working mode it can respond to signals emitted by wireless detectors in this zone and is not subject to pre set power on power off time It can respond to operations of emergency button and can be applied in p...

Page 25: ...etectors in zone 02 which is an emergency zone Firstly set this wireless detector in alert mode power the host off press the Function key and at the same time power the host on and then release the Function key At this time the screen will display 01 0 10 Press key to set zone number to 02 and at the same time the screen will display 02 0 10 Press key and the screen will display 02 1 10 And then p...

Page 26: ...st List of of of of Optional Optional Optional Optional Parts Parts Parts Parts 1 Solar Powered Wireless Detector Series 433Mhz 2 12V12Ah Backup Battery 3 Clock Module It works normally when the host is powered off 4 DC12V15W Active Siren XII XII XII XII Simple Simple Simple Simple Failure Failure Failure Failure Recovery Recovery Recovery Recovery Failure Symptom Failure Reasons Failure Recovery ...

Page 27: ...tenna It is recommended to use an independent power socket Avoid close to devices with high electromagnetic radiation Alarm information can not be received in some defense zones The code for this zone has been deleted This zone has been bypassed by the host Relearn code under the direction of the distributor Arm this zone again according to user manual Detector Misinformation The installation posi...

Page 28: ...e extension should be parallel connected with the output terminal of the wireless receiving host extension Facsimile equipment gives out urgent beep beep sound when working The input terminal of outside line of the wireless receiving host is not connected with the output terminal of facsimile equipment extension Connect facsimile equipment with the output terminal of the wireless receiving host ex...

Page 29: ...ocal local local local radio radio radio radio regulatory regulatory regulatory regulatory authority authority authority authority 2 2 2 2 This This This This product product product product is is is is an an an an advanced advanced advanced advanced wireless wireless wireless wireless alarm alarm alarm alarm device device device device but but but but we we we we can can can can not not not not g...

Page 30: ...s users users shall shall shall shall routinely routinely routinely routinely test test test test the the the the system system system system to to to to ensure ensure ensure ensure its its its its stable stable stable stable and and and and reliable reliable reliable reliable operation operation operation operation If If If If any any any any abnormality abnormality abnormality abnormality is is ...

Reviews: