TECHNICAL

PROCEDURE

AK-201 UNIVERSAL LOAD
SCALE KIT

SUBJECT:

Operator’s Guide

LIT NO:

L597

DATE:

March 2008

REVISION:

D

AK-201 UNIVERSAL LOAD SCALE KIT
(ULSK) DESCRIPTION

The AK-201 universal load scale kit provides an 
economical and accurate way to determine axle load.
The 2½-inch diameter gage directly indicates axle
load, making it easy to use. The gage is easily 
calibrated to provide consistently accurate readings
and is available in both dry and liquid-filled models.
The AK-201 is also available with or without a 
manual dump feature. The AK-201 has the same
footprint and mounting bolt pattern as other
Hendrickson load scale kits and comes with push-to-
connect fittings.

IMPORTANT:

For maximum accuracy, the AK-201
must be properly calibrated before use.
However, the liquid-filled models are
factory-calibrated and therefore do not
need to be calibrated.

If you have a liquid-filled model, skip
the following Calibration Procedure and
proceed to the section titled OPERATING
THE AK-201.

If you have a dry model, it must first be
calibrated before it can be expected to
deliver a reliable indication of axle load.
To calibrate, continue with the following
procedure.

CALIBRATION PROCEDURE (DRY
MODELS ONLY)

PREPARE THE TRAILER FOR CALIBRATION

1.

Load the trailer to its maximum legal load (or as
close as possible).

2.

Locate a drive-on scale that gives reliable weight
measurements. Position the trailer on the scale.

3.

During calibration, maintain the proper air
pressure in the trailer air reservoir.

CALIBRATING THE AK-201

IMPORTANT:

The gage valve should always be in the
GAGE OFF position unless performing a
calibration or measuring axle load. If left
in the GAGE ON position while operating
the vehicle, the gage will be damaged.

Figure 1. Gage valve in the GAGE ON position (shown with

optional dump feature)

Summary of Contents for AK-201

Page 1: ...ry calibrated and therefore do not need to be calibrated If you have a liquid filled model skip the following Calibration Procedure and proceed to the section titled OPERATING THE AK 201 If you have a dry model it must first be calibrated before it can be expected to deliver a reliable indication of axle load To calibrate continue with the following procedure CALIBRATION PROCEDURE DRY MODELS ONLY ...

Page 2: ...xle 7 Replace and firmly secure the plexiglass face cover by rotating it clockwise on the gage 8 Rotate the gage valve the upper ball valve if equipped with the optional air dump feature clockwise to the GAGE OFF position figure 2 OPERATING THE AK 201 IMPORTANT The gage valve should always be in the GAGE OFF position unless performing a calibration or measuring axle load If left in the GAGE ON pos...

Page 3: ...DE HEIGHT CAUTION DO NOT operate the vehicle for prolonged periods of time with the suspension riding on the air spring bumpers Damage may occur to the air suspension system 1 Rotate the dump valve the lower ball valve counterclockwise to the RIDE position figure 2 Allow the air system to fully charge OPTIONAL AK 201 ENCLOSURE An optional enclosure for the universal load scale kit is available fig...

Page 4: ...3 23 AAL AAT AANL AANT 23K Low Pressure Air Spring Dry 0 25 000 C 5 25 AAL 25K AAT 25K Dry 0 25 000 C 5 25 AAL 30K AAT 30K Dry 0 30 000 E 9 29 AAEDL 30K AAEDT 30K Dry 0 30 000 E 9 29 AAZL 23K AAZL 46K Dry 0 23 000 B 3 23 AAZNT 23K AAZNT 46K Dry 0 23 000 B 3 23 HK190T Dry 0 23 000 B 3 23 HK230T Dry 0 23 000 B 3 23 HKANT 23K HKANT 46K Dry 0 23 000 B 3 23 HKANT 40K Dry 0 20 000 A 1 21 HKAT 50K HKAT 6...

Reviews: