UFH-THERM-RD 

Summary of Contents for UFH-THERM-RD

Page 1: ...UFH THERM RD...

Page 2: ...2...

Page 3: ...IDE GB RF Digital Thermostat 4 15 GUIDE UTILISATEUR F Thermostat Digital RF 16 27 HANDLEIDING NL Digitale thermostaat RF 27 38 BEDIENUNGSANLEITUNG D Funk LCD Raumthermostat xx xx 0 18 86O I xxxxxxxxxx...

Page 4: ...r floor heating cooling managed by actuators Possibility to regulate on o Air sensor only o Floor sensor only o Air Floor combined with floor sensor use as limiter KEYBOARD Navigation key left and min...

Page 5: ...ndication 3 Cooling demand indication 4 Batteries weak 5 If lit XS 6 GLVSOD V WKH PHDVXUHG WHPSHUDWXUH 6 Measured temperature or setting temperature 7 C or F indicator 8 Moving bars when transmitting...

Page 6: ...thermostat needs to be turned OFF The display will be turned off and all parameters are saved Careful in this mode your installation can freeze COMFORT operating mode The comfort temperature will be f...

Page 7: ...D operating mode The comfort temperature will be followed all the time By pressing or keys the comfort temperature starts to blink and can be adjusted The measured temperature OK reappears after a few...

Page 8: ...range 5 C 37 C by 0 5 C step Regulation characteristics Proportional Integral regulation PWM adjustable see installation menu Electrical Protection Class II IP30 Power Supply Battery operated life 2...

Page 9: ...parameter to be adjusted Press OK to toggle the parameter setting or edit the value If the value starts to blink you can use or keys to adjust this value Press or keys at the same to reset this value...

Page 10: ...is parameter to exit the parameters menu end come back to the main display JO Type of degrees displayed C Celsius F Fahrenheit J1 Operating mode Hot for heating application CLd for cooling application...

Page 11: ...aking function of the pump when WKH SXPS KDVQ W ZRUNHG on a particular day start it up for one minute each day Pmp Function activated no Function deactivated J6 Selection of the sensor used for the re...

Page 12: ...a specialist A0 Calibration of the internal sensor The calibration must be done after 12Hours working with the same setting temperature To check the temperature in the room put a thermometer at 1 5M...

Page 13: ...ed as floor sensor the thermometer should be put on the floor FL Lower limitation of the floor temperature Only effective if the external sensor is connected and selected 5 C Adjustable From 5 C WR FH...

Page 14: ...ver leaflet for this After you have just pressed OK key during 5 sec thHQ WKH GLVSOD RF PXVW EH DSSHDUV The thermostat sends its configuration address by radio signal Check the good reception on the U...

Page 15: ...15...