ZEUS X Series
4-CH Power Amplifiers with Crossover
16
If the switch CH3 LINK CH1 is in ON position you can configure the amplifier with
1 input and 4 outputs. In this case CH1 must be the input. Please connect the
outputs as shown above.
7.4. BRIDGE MODE
CH3
CH1
CH 3
CH 1
2+
1+
2+
1+
1+
2-
2+
1-
BRIDGE MODE with a mono input and a mono output, allows you to add the
respective signals of the two amplification channels and make them available on
a single output. The input signals of channel 1 and channel 3 will be sent respec
-
tively to CHANNEL 1 OUTPUT and CHANNEL 3 OUTPUT. Use the channel 1 and
channel 3 controls to adjust the volume.
To set the amplifier in the BRIDGE MODE, set the MODE selector(5) to the BRIDGE
position (To Right) and connect the output as shown above.