Helvest FleX HP100 User Manual Download Page 1

Helvest

 FleX Motherboard HP100 - User Manual

Helvest

® 

Flex HP100 user manual

1. GENERAL PRODUCT PRESENTATION

1.1 What is the Helvest Flex system?

The Helvest Flex system is designed to easily assemble electronic circuits for the
control of a model railroad. Decoders can be made to manage switches, signals and
other accessories, presence detectors, and other future developments.
The HP100 motherboard is the heart of the system. It manages a maximum of three
modules, automatically identifying them and activating their specific functions. 
There are two types of modules:
- “net” module: it communicates with other units, with the digital control unit or with
the   PC   (e.g.   it   manages   the   DCC   digital   signal   to   control   the   switches,   or
communication buses to report the presence of trains).
- “Layout" module: manages the devices present on the layout (for example it moves
the switches or receives the data from the sensors that detect the presence
of the trains).

The main advantages of the system are:

- You can configure it according to your needs by combining the additional modules
as you wish.
- It is extremely easy to make changes, modifications or updates to the modules.
- You can expand it with new modules that will be available in the future.

1.2 HP100 components

The main parts of the board are identified in Figure 2:

1) Area for " Layout " type module for connection to the layout.
2) Area  for  "  Net  "  type  module  for  communication  with   the   digital
control panel, the PC or other boards. 
3)   Connectors   for   the   insertion   of
"Layout" modules
4)   Connectors   for   the   insertion   of   the
"Net" module.
5) Mounting holes
6) Power supply connector
8) Power LED.

2  HELVEST

 

FLEX SYSTEM BASIC

OPERATIONS

2.1 Mounting the board

The complete board must be mounted in such a way that it DOES NOT
touch   anything   during   operation.   In   particular,   it
must   not   come   into   contact   with   any   metallic   or
flammable materials.
For temporary installations, it can be placed on a
non-flammable   insulating   surface   (plastic,   glass,
ceramic floor, etc...).
For fixed layouts, it is recommended to mount it by
screwing the HP-100 onto the wooden structure with
the   screws   and   spacers   provided   (fig.   3).   This
operation   must   be   done   before   inserting   the
additional modules.

2.2 Installing the additional modules

The installation of the additional modules must be carried out with the power supply 
switched off.

You can install:

Fig. 1

Plastico

Layout

HP100

Net

PC o centrale 

digitale

Layout

Moduli Layout

Fig. 2

Power

Reset

1

1

2

layout module 1

layout module 2

net module 

3

3

3

3

3

3

4

4

4

5

5

5

5

6

7

8

Fig. 3

Reviews: