General information:
The control panel is meant to be flush or surface mounted outside the sauna room.
The enclosure class is IP X4.
The package includes:
-
A control centre
-
An OLET 19 thermostat sensor with a 5 m heat-resistant cable
-
An LiYY cable, 10 x 0.25, 10 m
This control centre is compatible with the following heaters:
-
1707
– X – 0405
(SKSG -
…- DE)
-
1712
– X – 0405
(SKSM -
…- DE)
-
1712
– X – 040520
(SKSM -
…- DEW)
-
1116
– X – 0405
(SKLR -
…- DE)
-
1118
– X – 0405
(SKLT -
…- DE)
-
1120
– X – 0405
(SKLW -
…- DE)
Please follow the manufacturer's installation measurements.
One sauna room can be fitted with a single sauna heater.
The heater and control centre may be connected to the electrical network only by an authorised person in accordance with the
currently valid electrical installation regulations.
NOTE! Before turning the sauna heater on, make sure that the sauna room is suitable for use
.
OVERVIEW
GENERAL:
Backup function
The unit has a backup time of approximately 60 minutes.
In the event of a power outage, the unit will remain operational for 60 minutes.
If the power outage exceeds 60 minutes, the unit will shut down all currently running functions
and return to standby mode.
All programme values and settings are stored in a permanent memory, which is not affected by
power outages.
Quick functions
Factory settings: Run time 2h and temperature 80°C.
Temperature units
The sauna room temperature can be displayed in either Celsius (°C) or Fahrenheit (°F).
Change of the display units is possible when the unit is in standby mode (display off):
-
Press and release the Temperature button. The display will indicate the currently selected
temperature unit (CELC or FAHr)
-
Within 5 seconds press either the Arrow up or Arrow down button to change the displayed
temperature unit
-
Accept the change by pressing the OK button or by waiting 5 seconds. The unit will return
to standby mode (display off)
Sauna run time
The maximum sauna run time is normally 6 h. Jumper on connector J3 disconnected.
The maximum run time is 12 h, when jumper on connector J3 is installed.
- temperature setting: 0 - 110°C
- run time: 6h or 12h
- preset time 0
– 24h
Alarms
The unit will indicate when the high temperature limiter is activated.
The display will show:
Err1
.
The alarm is reset by pressing the
ON_OFF
button.
Note!
Before the unit is reset the cause of the overheating must be checked / corrected by a
qualified person.
Temp setting
Setting 0-110°C. PID control.
Power outputs are set in ratios of 0/0, 1/3, 2/3 and 3/3, depending on the difference between
set and measured temperatures.
Installation and User Manual
Digi 1