Helmholz 700-972-0RB12 Instruction Manual Download Page 1

 

 
 

PROFIBUS Compact Repeater 

700-972-0RB12

 

 

Instruction Manual 

Edition: 3 / 30.11.2009 

 

 

 

 

 

 

Order number of instruction manual: 900-972-0RB12/en 

Systeme Helmholz 

GmbH

 

z

 

Hannberger Weg 2

 

z

 D-91091 Großenseebach 

Phone: +49 9135 7380-0

 

z

 Fax: +49 9135 7380-110 

z

 E-mail: [email protected]

 

z

 Internet: www.helmholz.com 

Summary of Contents for 700-972-0RB12

Page 1: ...tion Manual Edition 3 30 11 2009 Order number of instruction manual 900 972 0RB12 en Systeme Helmholz GmbH z Hannberger Weg 2 z D 91091 Gro enseebach Phone 49 9135 7380 0 z Fax 49 9135 7380 110 z E ma...

Page 2: ......

Page 3: ...pyright 2009 by Systeme Helmholz GmbH Hannberger Weg 2 91091 Grossenseebach Germany Note We have checked the content of this manual for conformity with the hardware and software described Nevertheless...

Page 4: ...f this document Edition Date Revision 1 30 08 2007 First edition 1 1 25 02 2008 Lower modifications 2 15 07 2009 Lower modifications 2 1 26 10 2009 New pictures and lower modifications 3 30 11 2009 Lo...

Page 5: ...Symbols used 7 2 Installation and Mounting 8 3 Short Description of the PROFIBUS Compact Repeater 9 3 1 Application and function description 9 3 2 The LED display and its meaning 9 3 3 Connections 10...

Page 6: ...main active in all modes of the machine system The system must not enter an undefined restart Faults occurring in the machine system that can cause damage to property or injury to persons must be prev...

Page 7: ...rovides the installing technician with all the necessary data The PROFIBUS Compact Repeater is intended for use in a PROFIBUS network only For that reason the configuring engineer user and installing...

Page 8: ...S Compact Repeater is plugged directly into the SUB D female connector of the PROFIBUS station instead of the normal PROFIBUS device connector It is locked in place with the two screws on the sides Vi...

Page 9: ...ped into the PROFIBUS in place of a normal PROFIBUS connector This permits the extension segmentation or branching of the PROFIBUS without extensive installation The device is plugged into the PROFIBU...

Page 10: ...tation Segment 1 A1 green cable B1 red cable Segment 2 A2 green cable B2 red cable SUB D female connector An operator panel or programming unit can be connected to the Sub D female connector of the PR...

Page 11: ...block diagram see Fig 3 2 The bus cables are always connected as stub lines Do not connect Ax Bx and Ax Bx by cable Fig 3 1 Block diagram of the repeater For long bus lines repeaters can be connected...

Page 12: ...3 Application example of more than 32 stations Up to 32 stations can be connected to one repeater in a subnetwork The number of stations can be increased still further by interposing further repeater...

Page 13: ...rate 9 6 Kbps to 12 Mbps automatic detection Protocol PROFIBUS DP per EN 50 170 Connector SUB D 9 way Special features Quality assurance per ISO 9001 2000 Maintenance Maintenance free no battery 4 2...

Page 14: ...G Bus connector for PROFIBUS 90 without PG 700 972 0BA12 Bus connector for PROFIBUS 90 with PG 700 972 0BB12 Bus connector for PROFIBUS 35 without PG 700 972 0BA41 Bus connector for PROFIBUS 35 with P...

Page 15: ...ibusstecker de Siemens Manuals Installing and Wiring the S7 300 S7 400 S7 300 Module Data Profibus DP DPV1 Manfred Popp H thig Verlag Profibus Handbuch Max Felser Berner Fachhochschule CH 3400 Burgdor...

Page 16: ...Notes 16 PROFIBUS Compact Repeater...