Helmholz 700-158-3PN02 Quick Start Manual Download Page 1

 

Helmholz GmbH & Co. KG | Hannberger Weg 2 | 91091 Großenseebach | Germany 

12.10.2021

 

Phone +49 9135 7380-0 | Fax +49 9135 7380-110 | [email protected] | www.helmholz.de 

Quickstart Guide 

PN/PN Coupler 

Order number: 700-158-3PN02 
For firmware V2.0 and above 
 

Version 

en 

Summary of Contents for 700-158-3PN02

Page 1: ...berger Weg 2 91091 Großenseebach Germany 12 10 2021 Phone 49 9135 7380 0 Fax 49 9135 7380 110 info helmholz de www helmholz de Quickstart Guide PN PN Coupler Order number 700 158 3PN02 For firmware V2 0 and above Version en 7 ...

Page 2: ...f the PN PN Coupler 4 4 Connection 4 4 1 Power supply 4 4 2 Network 5 5 Install GSDML file 5 6 Configuration in TIA Portal 6 6 1 IO Configuration 7 6 2 Parameterization of the PN PN coupler 8 6 3 Assign a name to the PN PN coupler 9 7 Web interface of the PN PN Coupler 10 8 Technical data 12 9 LED status information 13 ...

Page 3: ...be closed and possibly locked during operation The consequences of improper use may include personal injury to the user or third parties as well as property damage to the control system the product or the environment Use the device only as intended Operation Successful and safe operation of the device requires proper transport storage setup assembly installation commissioning operation and mainten...

Page 4: ...ing the FIFO principle cross network The data record transfer uses standard PLC handling blocks The integration into the PLC engineering tool is enabled by a GSDML file an additional extra configuration software is not necessary The configuration of the I O data to be exchanged is done in the Siemens engineering tool 4 Connection 4 1 Power supply The PN PN coupler must be supplied with DC 24 V at ...

Page 5: ...jected to TNVs The interfaces X1 and X2 are logically separate networks and not physically connected Thus a clear separation between both machine networks is possible A network penetration with other functions by the PN PN coupler is not possible The configured values are exchanged in the PN PN Coupler only as IO data between both network sides 5 Install GSDML file Please download the GSDML file G...

Page 6: ...the device list Provide the PN PN Coupler with a PROFINET name under General and check the Ethernet address for the device Connect the PROFINET network of the PROFINET controller with the PN PN Coupler The two PLCs can be in the same project as shown above or in different projects The IP addresses of the PN PN Coupler must be different on both network sides X1 X2 but may be located in the same sub...

Page 7: ...t Combined IN OUT modules are also available The sequence and the sizes of the modules must always be selected consistently with the modules on the opposite PROFINET side Example A 2 byte Input module in slot 2 of the left PROFINET side X1 requires a 2 byte output module in slot 2 of the right PROFINET side X2 For transferring PROFISAFE messages between two failsafe CPUs the PROFIsafe IN OUT modul...

Page 8: ...DIA The validity of the data is displayed in the bit with the lowest value Bit 0 of the first input byte of the corresponding PROFINET side 0 data could not be transmitted 1 data is all valid Data validity diagnostic Sending of a diagnostic message to the PLC when the data is not valid Status webpage Display of webpage on the network interface The parameters can be set separate on both network sid...

Page 9: ...nction which you can access with the right mouse button or in the Online menu if the PN PN Coupler is selected Use the Update list button to search the network for PROFINET stations With Assign name the PROFINET device name can be assigned to the device If the PN PN coupler has received the correct PROFINET name it is recognized and configured by the PLC If the configuration is correct the PROFINE...

Page 10: ...device is accessible if it is activated in the PROFINET configuration If the web page of the device is not available please check the Web page parameter in the PROFINET configuration See chap 6 2 The menu Module Configuration shows an overview of the IO configuration of all slots with a short view of the actual data Calling up the website can influence the transmission speed of the device ...

Page 11: ...update please download the current firmware under the following link or scan the QR code http www helmholz de goto 700 158 3PN02 tab software The firmware file can be recognized by the file extension HUF Helmholz Update File and is encrypted to protect it from modification ...

Page 12: ...matic addressing Topology detection LLDP DCP diagnosis alarms Status indicator 9 LEDs function status 8 LEDs Ethernet status Voltage supply DC 24 V 18 28 V DC Current draw max 210mA Power dissipation max 5 W Dimensions D x W x H 32 5 x 58 5 x 76 mm Weight approx 135 g Certifications PROFINET Conformance Class B Protection rating IP 20 not evaluated by UL Relative humidity 95 non condensing Mountin...

Page 13: ...to operate RJ45 LEDs X1 P1 P2 und X2 P1 P2 Green Link Connected Orange Act Data transfer at the port active The contents of this Quick Start Guide have been checked by us so as to ensure that they match the hardware and software described However we assume no liability for any existing differences as these cannot be fully ruled out The information in this Quick Start Guide is however updated on a ...

Reviews: