Operating Instructions • CPK hybrid • 11-2021 • v04 • 106-29004
Design and function
11
3 .2 Functional description
3 .2 .1 CPK hybrid tool
10
6
5
4
9
7
8
15
3
2
13
14
12
11
1
1 Actuator service flap left
2 Actuator bandoleer cutter
3 Enter button to confirm a selection in the navigation menu and increment switch
for display settings
4 Socket for connection to power pack
5 Select and reset button for selecting a menu for display settings
6 LED status indicator
7 Battery pack/cover for battery pack
8 On/off switch for battery pack
9 Start trigger
10 Box for waste material
11 Display with touch-sensitive controls
12 Front cap with level sensor, upper and lower jaws
13 Catch
14 Drum
15 Cable tie bandoleer
The CPK hybrid is an electrically powered or battery
powered system for bundling electrical wires, for exam-
ple, and for securing parts of various kinds with T18RA
cable ties, 100 mm × 2.5 mm × 1 mm (L × W × H).
Force and quality of the binding can be software-
controlled or set by means of the display on the device,
The items to be bundled have to be positioned between
the jaws and against the front cap. The device then
closes the tie as soon as the trigger is pressed. If a fault
occurs, messages appear on the display to guide the
user through the recommended fault-diagnosis routine,
Process data of various kinds are collected during use.
These data can be analysed by PC software and used to
document process capability, for example. In addition,
the operator is notified if the tension force exceeds the
preset,
"HT Data Management" on page 18
.
3 .2 .2 Power pack CPK
Data
Signal
Power
Power pack CPK
6
2
3
4
5
1
1 Main switch
2 LED indicator
Power
:
Green: Power pack ON
3 LED indicator
Signal
:
Green: CPK hybrid connected and ready,
Red: Error
Yellow: Binding cycle active
Blue: Navigation in main menu, binding not possible
4 LED indicator
Data
:
Green: PC connected; CPK hybrid connected; USB stick found; USB stick can be
removed,
Red/blue flashing: Data are being written to USB stick
5 USB port for exporting process data to USB memory stick
6 Socket for connection to CPK hybrid
max. 250V~
In: Last Tie
Out: Error
Out: Busy
Serial port
3
1
2
1 Socket for foot pedal
2 USB port for connection to PC (for the HTDM)
3 Socket for power supply
In automatic systems, the CPK hybrid can be integrated with
the separate power pack with control box (106-00110) via a
serial interface.
3 .2 .3 Battery pack with charger
The CPK hybrid can be operated independently of the
mains with a battery pack. The battery pack is sold
separately and is charged with the charger that comes
with the battery pack.
The connection for the battery pack can be found in the
base plate of the handle.