74 / 179
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without
express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
21.04.2020
Version 1.18.0
Installation
APS-90, APS-180 and APS-90-Outdoor-PoE
Digital input with an IR-
sensor
5.4
Wiring examples
5.4.1
APS-90E-IO and APS-90-IO
The following example shows a wiring diagram with an infrared sensor
as digital input.
Observe the following electrical limit values:
I
max
= 100 mA
U
max
= 30 VDC
Fig. 49: APS-90 Digital input with an IR-sensor