6 Sensors
18
Digital Governor Basic System PANDAROS II
6.4.2
Boost pressure sensors
The boost pressure sensors are also available in an additional housing with terminal
strip.
Measuring range
0 … 2 bar, 0 … 5 bar or 0 … 10 bar
Over pressure
4 bar resp. 10 bar resp. 16 bar
Supply voltage
12 … 36 V DC
Output signal
4 … 20 mA
Storage temperature
-55°C … +100°C
Ambient temperature
-40°C … +100°C
Protection grade
IP 65
Vibration
< 2 g, 5 … 500 Hz
Shock
< 50 g, 11 ms half-sine wave
Connection
DIN 43650-A or terminal strip, 2-line system
6.4.2.1
Boost pressure sensor with plug
Fig. 6: Boost pressure sensor with plug
Pressure Sensor
EDV- No.
Maximum Operating
Pressure (bar rel.)
DSL 01-2
600-00-057-00
2
DSL 01-5
600-00-057-01
5
DSL 01-10
600-00-057-02
10
92
12
2
R
3
/8
"
Ø
3
0
128
3
0
,5
Ø 19
PG9
SW 24
3
3
,5
53