HEINRICH VAC/C Product Manual Download Page 1

Digital Network 
Public Address & Voice Alarm System

DIGITAL NETWORK PUBLIC ADDRESS

& VOICE ALARM SYSTEM

HEINRICH

HEINRICH LIMITED,    

71-75 SHELTON STREET COVENT GARDEN LONDON

T: 

+442032860291 

W: 

www.heinrichlimited.com  

E: 

[email protected]

VAC/C

Thanks for using HEINRICH Digital Network Public Address & Voice Alarm System.

For better operation, please read this manual carefully before operating the system.

Summary of Contents for VAC/C

Page 1: ... HEINRICH HEINRICH LIMITED 71 75 SHELTON STREET COVENT GARDEN LONDON T 442032860291 W www heinrichlimited com E info heinrichlimited com VAC C Thanks for using HEINRICH Digital Network Public Address Voice Alarm System For better operation please read this manual carefully before operating the system ...

Page 2: ...ion of the network bandwidth only 24 different audio signal can be sent to the system partitions audio priority can be configured through software when configured with backup host the priority of the audio signals come from one host can be the same the priority of the audio signals come from diferent hosts must be different Some icons are described as belows Loop playback Single cycle Order play S...

Page 3: ...ue to high temperature and stop working 2 Do not install the system device or store in a dusty humid place otherwise it will affect stability or cause intermittent fault when the system is working 3 System equipment should be as far away from the strong magnetic field generated by the device in case of high electromagnetic interferences system equipment normal operation 4 System equipment are desi...

Page 4: ... lines Automatic redundancy It is a more stable system with low maintenance cost in the future If you are looking for a perfect PA system EVAC System is your best choice It is widely used for five star hotel office building super market and stadium Compared to EVAC System it is more stable with better audio output which could bring you perfect feeling 3 Products Introduction 3 1 Voice alarm system...

Page 5: ...ule testing 5 7 Panel emergency PTT push to talk MIC 5 Color status explaination Off PTT work normally Green PTT being broadcast Yellow Open circuit fault PTT microphone internal short circuit fault 6 Aerial socket can connect PTT MIC 7 PTT MIC hook Before pressing PTT switch the host will make the following judgment the performed functions as below for reference If user selects partition then it ...

Page 6: ... status indicator Off indicates the current evacuation voice warning voice background music work normally Yellow indicates the current evacuation voice warning voice background music has faulty 14 The host feet 15 Background music storage SD card to store background music can be mp3 and wma format note the number of song in the card can not be more than 100 16 Multi function reset button RESET OFF...

Page 7: ...t circuit interfaces connect it will be off in normal mode 3 emergency reset input interface when system is operating in emergency mode this interface reset into normal operation mode if input a low level signal which is bigger than 0 5S 10 Microphone line input 1 for external users MIC CD MP3 TUNER and some other audio signal when input is unbalanced 6 3 plugs audio signal as MIC input when input...

Page 8: ...ut power 1kHz Frequency Response 20Hz 20kHz Sensi vity 350mV Impedance 10kΩ SNR 70dB Record Output Sensi vity 200mV SNR 70dB Contact output System fault relay output Short circuit no voltage Fire interlocking relay output Short circuit no voltage 8 relay programmable output Short circuit no voltage Programmable DC24V power output DC 24V 1A Level Mode Up to 3 3V Short circuit mode No voltage short ...

Page 9: ...rage Type SD card Message Number 65535 programmable up to 255 Save me 10 years Data format HEX Storage Type Nand Flash Message Number 1000 Save me 10 years Dimensions L x W x D 484 132 449 mm 19 inch width 4U Net Weight About 8 0 kg Installa on Desktop or 19 inch rack Color Black Opera ng temperature 5 40 Storage temperature 20 70 Rela ve temperature 95 Environmental requirements Mechanical specifi...

Page 10: ...ind out specific fault module type The status of each sub menu in XX Status Menu is shown by icons and text icons indicates its current image of the type of device the text indicates its current working state green font indicates normal operation yellow font indicates failure white font is the default display font regardless of device module status in addition to the text description of all menu i...

Page 11: ... background music for background music player control system self test six menu items a total of nine main menu items the interface for the functional operation of the rightmost keys function interface associated with the current such as the top means to return to the previous menu on the current menu indicates the page Up indicates down stands directly into the Main Menu means direct access to th...

Page 12: ...configured in grey while there is not battery connected It will show as below if system is equipped with battery EVAC Host 01 Charger Status Network Status Online or Offline detect communication connection of charger it will show as Online when it s normal AC Power Normal or Fault it will show as Fault while system is powered by 24V backup power and main power is disconnected Battery 3 kinds of st...

Page 13: ...t line shows working status Normal or Fault BGM 100 figure represents songs quantity the next line shows working status Normal or Fault 5 This icon shows current status of remote microphone Normal Fault Note system default setting doesn t configure it Press this icon and enter the submenu to check current remote microphone status The submenu Host 01 Remote MIC01 is shown below Host 01 Remote MIC01...

Page 14: ...nnel 01 02 03 04 05 06 07 08 host 8 channel interface INPUTS MODE LEVEL and SHORT Inputs In Electric Level mode it will show as Normal when it s normal show as Open when it s open circuit show as Triggered when it s in fire alarm In Short Circuit mode it will show as Normal when it s normal show as Triggered when there is short circuit signal input Outputs output interface can be controlled manual...

Page 15: ...on shows in grey and inoperable SAfter entering Host Status Main Menu by pressing press to check working status of current host voice messages and files total in SD card Note EVAC and prompt voice can only be checked in this way BGM also can be checked by pressing in Main Menu to enter BGM control interface then it will show BGM working status 4 2 View Working Status of Device Physical Zone View w...

Page 16: ...s the set value or charger is faulty it will shown as Unconfigured in grey while there is not battery connected Only when system has equipped with backup power you can enter and view To view working status of other amplifier controller s backup power please press up and down icon Amplifier Changeover 01 Charger Status 01 Network Status Online or Offline detect connection to charger it will show as...

Page 17: ...working status of spare amplifier it shows as Normal when spare amplifier works well it shows Fault when amplifier output AMP loop is short circuited or faulty If sleep function is on and more than 3 minutes without input signal it will switch to sleep mode to save power configure in software Physical Zone Normal Open Short Ground It shows channels working status of current main amplifier it shows...

Page 18: ...t port it will show as Short when connection of input circuit is short circuit it will show as Trigger when emergency is triggered In Short Circuit mode it will show as Normal when it s normal it will show as Trigger when there is short circuit input signal Outputs output interface can be controlled manually short circuit or open circuit automatic trigger output mode can be configured in PC softwa...

Page 19: ...er status Normal Fault Unconfigured It will show as Normal in green while host has detected that DC 24V is connected it will show as Fault in yellow while battery voltage is low battery is disconnected operating temperature exceeds the set value or charger is faulty it will shown as Unconfigured in grey while there is not battery connected Only when system has equipped with backup power you can en...

Page 20: ...ell it shows Fault when amplifier output AMP loop is short circuited or faulty If sleep function is on and more than 3 minutes without input signal it will switch to sleep mode to save power configure in software Physical Zone 01 02 03 04 05 06 07 08 it means that system is equipped with eight main amplifiers If system is just equipped with four main amplifiers it will show 01 02 03 04 Sub Zone St...

Page 21: ...lectric level mode it will show as Normal when input end test normal It shows open circuit when input end is no external connection trigger circuit is disconnected it shows short circuit when input ends or trigger short circuit it shows trigger in the condition of short circuit whenTrigger emergency it shows as Normal when testing is normal Output It can be manual control output interface and is a...

Page 22: ...dentity verification interface first to enter a security password factory default password 666666 then press to enter the System Settings Main Menu press abandon the current operation return to the main menu press to delete erroneous input In the System Settings Main Menu click the network parameters submenu enter into Network Parameters View Menu you can view the system configuration of hosts and...

Page 23: ...enu click the telephone interface submenu enter into telephone interface menu you can view the status of settings the phone can be preset to adjust the input volume view the trigger time of help state and view the number of calls see telephone interface menu Host 01 telephone interface Prompt tone on off indicates the current remote telephone prompt tone is on off status can be set in the PC softw...

Page 24: ...y the user s password Old password enter present login password the new password interface Enter the 6 figures password which you want to set confirm password Enter the new password again and press to confirm Click Delete click return This password can be set and viewed in the PC software n the System Settings Main Menu click the submenu enter into touch screen calibration menu when clicked it wil...

Page 25: ...round music songs meanwhile after the implementation of the parti tion the partition of the status bar will display the playback of the information channel Zoning control menu Play to all zones 1 Firstly click the button 2 Then click the button when the icon in front of turns from grey to green the system will automatically play background music at the same time the partition of the status bar wil...

Page 26: ...ly play to the selected partitions As for the volume adjustment of the line inputs please refer to the EVAC host 4 line input volume Close partition play operation 1 Firstly tick the to choose the partition group that needs to be closed 2 Then select the button you can shut it down It is invalid for EVAC voice Close all zone play operation 1 Tick button 2 Tick to close all the zones It is invalid ...

Page 27: ...w blinking red at the same time the host of Logo standby interface will activate emergency mode icon 1 2 In the main menu interface click on the sub control enter Partition Control Menu 1 3 Under the Partition Control menu select for the partition you want to play or select 1 4 And then click on the or button when the indicator button change from gray to be green After Green the system will automa...

Page 28: ...triggered emergency when receiving the corresponding trigger signal and execute the emergency broadcast signal to the related zones Note 1 Triggering line 1 interface contacts you can specify a certain way or multiple partitions output and it can be set on PC software 2 The trigger input contacts according to the level of short trigger mode or short trigger depending on PC software settings such a...

Page 29: ...contact after the host VAC C received short trigger reset signal fire the system will go into the reset state EMERGENCY push button switch will turn from slow red flashing to be fast red flashing after flashing red stop reset is finished 3 Reset operation on fireman microphone When the EMERGENCY switch on from fireman microphone Microphone panel system status will be in the reset state of emergenc...

Page 30: ...priority data from Audio priority configuration according to actual needs level digital you can adjust priority configuration on VAC C Description The lower the priority number the higher priority 0 is the highest priority 2 Priority configurations on zone amplifier 8 Zone Voice Alarm Amplifier 1 Open the PC computer install EVAC System PC software then click Device Configuration under configura t...

Page 31: ... Priority Configuration window the user can adjust the partition local audio and network audio amplifier priority sequence upon demand select audio hold down the left mouse button and drag up or down move change their sequence to set up the amplifier priority level Digital Network Public Address Voice Alarm System HEINRICH HEINRICH LIMITED 71 75 SHELTON STREET COVENT GARDEN LONDON T 442032860291 W...

Page 32: ...aker ground fault Through Setting on host VAC C and software EVAC System PC users can enable or disable the above detection on monitoring events The operation steps of starting and forbidding module detection in VAC C and PC EVAC System system can perfor real time detection and monitor to all the online equipments it connects The de tection and monitor must be conducted on the basis that the syste...

Page 33: ...d VAC C When the malfunction is detected the system will have the following situations 1 The buzzer in VAC C will ring on the system indicator will turn to yellow and flash and the LCD screen will show the malfunction 2 The buzzer in Microphone will ring on and the system state indicator will turn to yellow and flash The right detection way 1 Firstly press RESET OFF button on VAC C to top the syst...

Page 34: ...Digital Network Public Address Voice Alarm System BLOCK DIAGRAM HEINRICH HEINRICH LIMITED 71 75 SHELTON STREET COVENT GARDEN LONDON T 442032860291 W www heinrichlimited com E info heinrichlimited com ...

Page 35: ...ion can extend to 255 zones power partition can expand to 56 zones Digital Network Public Address Voice Alarm System HEINRICH HEINRICH LIMITED 71 75 SHELTON STREET COVENT GARDEN LONDON T 442032860291 W www heinrichlimited com E info heinrichlimited com ...

Page 36: ...lic Address Voice Alarm System Signal partition which can extend to 255 signal zones HEINRICH HEINRICH LIMITED 71 75 SHELTON STREET COVENT GARDEN LONDON T 442032860291 W www heinrichlimited com E info heinrichlimited com ...

Page 37: ...end to 255 zones power partition can expand to 56 zones Digital Network Public Address Voice Alarm System HEINRICH HEINRICH LIMITED 71 75 SHELTON STREET COVENT GARDEN LONDON T 442032860291 W www heinrichlimited com E info heinrichlimited com ...

Page 38: ...er partition can expand to 56 zones Digital Network Public Address Voice Alarm System HEINRICH HEINRICH LIMITED 71 75 SHELTON STREET COVENT GARDEN LONDON T 442032860291 W www heinrichlimited com E info heinrichlimited com ...

Reviews: