Introduction | Remote Desktop Manager (option 133)
2
HEIDENHAIN | TNC 640 | Conversational Programming User's Manual | 10/2017
127
Setting
Meaning
Input
Release USB mass memory
Not advisable with this connection
–
Calculator
Host name or IP address of the external computer. In the recom-
mended configuration of the IPC 6641, the IP address 192.168.254.3
is used
Required
User name
User name with which the connection should be logged on
Required
Password
Password for connecting to the VNC server
Required
Windows domain:
Domain of the target computer, if required
Optional
Max. waiting time (seconds):
When the control shuts down, it commands the Windows comput-
er to shut down. Before the control displays the message
You may
switch off now
, it waits for
<Timeout>
seconds. If the Windows
computer is switched off before the
<Timeout>
seconds have
expired, the control stops waiting.
Required
Force
If Force is not selected, Windows waits up to 20 seconds. This
delays the shutdown process or the Windows computer is switched
off before Windows has shut down.
Required
Restart
Reboot the Windows computer.
Required
Run during restart
Reboot the Windows computer when the control reboots. Effective
only if the control is rebooted using the shutdown icon at the bottom
right in the taskbar or if a reboot is initiated as a result of a change in
the system settings (e.g. network settings).
Required
Run during switch-off
The Windows computer is switched off when the control is shut
down (no reboot). This is the standard scenario. The
END
key will
then no longer trigger a reboot, either.
Required
Entries in the
Advanced
options
area
Available only to authorized specialists
Optional
Starting and stopping the connection
Once a connection has been configured, it is shown as an icon in
the Remote Desktop Manager window. Click the connection icon
with the right mouse key to open a menu in which the display can
be started and stopped.
Use the right DIADUR key on the keyboard to change to the third
desktop and back to the control interface. You can also use the task
bar to get to this desktop.
If the desktop of the external connection or the external computer
is active, all inputs from the mouse and the keyboard are
transmitted there.
When the HEROS 5 operating system is shut down, all
connections are canceled automatically. Please note, however, that
only the connection is canceled, whereas the external computer or
the external system is not shut down automatically.
Summary of Contents for TNC 640
Page 4: ......
Page 5: ...Fundamentals ...
Page 36: ...Contents 36 HEIDENHAIN TNC 640 Conversational Programming User s Manual 10 2017 ...
Page 67: ...1 First Steps with the TNC 640 ...
Page 90: ......
Page 91: ...2 Introduction ...
Page 130: ......
Page 131: ...3 Operating the Touchscreen ...
Page 144: ......
Page 145: ...4 Fundamentals File Management ...
Page 206: ......
Page 207: ...5 Programming Aids ...
Page 236: ......
Page 237: ...6 Tools ...
Page 281: ...7 Programming Contours ...
Page 333: ...8 Data Transfer from CAD Files ...
Page 355: ...9 Subprograms and Program Section Repeats ...
Page 374: ......
Page 375: ...10 Programming Q Parameters ...
Page 478: ......
Page 479: ...11 Miscellaneous Functions ...
Page 501: ...12 Special Functions ...
Page 584: ......
Page 585: ...13 Multiple Axis Machining ...
Page 650: ......
Page 651: ...14 Pallet Management ...
Page 664: ......
Page 665: ...15 Batch Process Manager ...
Page 673: ...16 Turning ...
Page 713: ...17 Manual Operation and Setup ...
Page 797: ...18 Positioning with Manual Data Input ...
Page 803: ...19 Test Run and Program Run ...
Page 843: ...20 MOD Functions ...
Page 881: ...21 Tables and Overviews ...