INSTRUCTION MANUAL

HEAVEN FRESH UK

©2008, HFUKENG HF 380 - 06/08

Summary of Contents for NatroPure

Page 1: ...INSTRUCTION MANUAL HEAVEN FRESH UK 2008 HFUKENG HF 380 06 08 ...

Page 2: ...on indicator sensors Long lasting high efficiency HEPA filter 99 97 collection rate Electrostatically charged plasma cell traps pollutants like a magnet Activated carbon filter traps chemicals gases and odours Germicidal UV lamp destroys micro organisms Air cleaning negative ions are circulated throughout the room Powerful yet quiet fan for maximum air circulation Washable pre filter to collect th...

Page 3: ...materials to cover this device Obstructed air inlets and outlets will result in abnormal operation of this device that may lead to fire or other accidents To prevent interference and distortion the device should be placed at least 1 meter away from the computer television or radio For safety reasons and to prevent fire or electric shock unplug the power cord from the electric outlet socket under t...

Page 4: ...TS Front View Control Panel Odour Sensor Receiver port Air Outlet Air Inlets Air Inlets Dust Sensor Bottom Stand CLEAN METAL GRID REPLACE FILTER RESET CLEAN METAL GRID REPLACE FILTER RESET Heaven Fresh UK HF 380 4 ...

Page 5: ... Back View Interior View COMPONENTS Heaven Fresh UK HF 380 5 ...

Page 6: ...his time also increase ventilation in the room as much as possible even opening a window if the air outside is at least fairly clean 3 Unplug the HF 380 then immediately plug it in turn it on and resume operation Unplugging the HF 380 then plugging it in again resets the clean air sensor s memory By first ensuring the air is as clean as possible and then immediately resetting the sensor will be mo...

Page 7: ...Odour odour odour odour odour EXPLANATION OF INDICATORS Heaven Fresh UK HF 380 7 ...

Page 8: ...OPERATING INSTRUCTIONS from Timer duration duration to turn off Heaven Fresh UK HF 380 8 ...

Page 9: ...ving please ensure that the filter is installed correctly with the Push the plasama dust collector towards the base of the device Use your foot or knee if needed to hold the base in place Push the two tabs inward and lift up the dust collector Hold the top of the unit where the control panel is down to help pull out the collector grid Place Heaven Fresh UK HF 380 9 ...

Page 10: ...from R Remove UV lamp before cleaning Use a slightly damp cloth to wipe clean avoid scratching the coating on the cover 9 11 with running CLEANING AND MAINTENANCE Heaven Fresh UK HF 380 10 ...

Page 11: ...the plastic housing for the metal dust collector gird Once this tab is open remove the dust collector Please wear protective gloves to avoid any cuts on your fingers CLEAN METAL GRID REPLACE FILTER RESET CLEANING AND MAINTENANCE 9 Heaven Fresh UK HF 380 11 ...

Page 12: ...toothbrush to clean removed or discarded this would result in cause rusting ensure that the unit is completely dry if you want to purchase use warm water Please beware not to damage any wiring while cleaning the dust collector CLEANING AND MAINTENANCE Heaven Fresh UK HF 380 12 ...

Page 13: ...cators would remaining glowing after turning on the unit While resetting the unit should remain plugged into the socket but the uint itself should be turned off The RESET button is inside the unit cannot be reached with finger Please use a toothpick or other sharp object to push the RESET button Replacing the UV lamp CLEAN METAL GRID REPLACE FILTER RESET CLEAN METAL GRID REPLACE FILTER RESET CLEAN...

Page 14: ...Take out Put back the sensor correctly after cleaning make sure that the cord is reconnected in the correct direction CLEANING AND MAINTENANCE Heaven Fresh UK HF 380 14 ...

Page 15: ...ed within the room such as from smoking It is also important to note that it can take some time to clean the room to the point where only one LED light is on indicating the air around the unit is purified Q Why does the Clean Air Monitor function keep switching back and forth A The Irritant Sensor can be affected by a cell phone or other wireless equipment Keep cell phones and other wireless equip...

Page 16: ...ake sure it is Has the unit been properly reassembled after being cleaned Please confirm The unit will not operate if the plasma dust collector or the front cover is not properly installed FREQUENTLY ASKED QUESTIONS Q Q Check the electrical discharge wires to make sure they have not been disconnected or broken If they are please fix or contact the distributor for a replacement Heaven Fresh UK HF 3...

Page 17: ... consumption 80 W High Setting Ion output 4 000 000 cm UV 20uw 254 Nanometers Dust Removal Rate 99 97 Noise Level dB Silent 20 Low 35 Med 45 High 52 Air Volume 106 Cubic Feet per Minute High Setting Dimensions 34 3 L x 25 4 W x 61 0 H cm Weight 6 8 kg 15 lbs Coverage Area 60 4 m 650 ft 6 Heaven Fresh UK HF 380 17 ...

Page 18: ...Fresh customer support at 0800 952 9962 www heavenfresh co uk for Return Authorization Number 2 Pack the product in its original carton and in the same manner in which you received it or as identical as possible 3 Include proof of purchase inside box along with the Return Authorization Number 4 Label and ship the unit freight pre paid to the address provided Other Conditions The provisions of this...

Page 19: ...ase fill in completely this Warranty Certificate Send it with the invoice and the unit postage pre paid and using the original packing box to your distributor Make sure to include the appropriate return postage for the package 2 Please enclose a short description of the damage fault or malfunction and the circumstances under which these problems arose Heaven Fresh UK HF 380 19 ...

Page 20: ... com 1 800 642 0367 UK sales heavenfresh co uk www heavenfresh co uk 0800 952 9962 Germany sales heavenfresh de www heavenfresh de 0800 66 47 259 France sales heavenfresh fr www heavenfresh fr 0800 900 991 Ireland sales heavenfresh ie www heavenfresh ie 1 800 550 457 Middle East sales heavenfresh ae www heavenfresh ae 971 06 557 3640 ...