background image

TR8100V Thermos t at   I nstructions 

ver 1.0 

LCD symbols  

See overleaf for further setting up information 

Setting the clock and day of the week 

This thermostat is fitted with a real time clock. It is essenti al that the clock time and day are set accurately if you requir e your programmed events  

1) Touch the time display and the time will start flashing. Use the up and down arrows to set the time.By holding the arrow  down the time will change faster.  

2) Press              to move to the Day setting and use the  u p and down arrows to get to the correct day. 

3) Press               to store and exit. 

to start on time. To set follow the steps below:  

Page1 

The buttons are locked 
Heating is turned on 

Automatic mode,  

Manual mode  

executes the programmed schedules   

The floor sensor is not being read by the thermostat 

Err 

Temporary temperature override 

Frost protection activated 

AUTO 

Override 

Symbol 

Symbol 

Event 

Event 

Program number 

Economy temperature 

Comfort temperature 

Configuration Menu  

To enter into the setting menu please follow the steps below: 

Step 3, Use the up and down arrows to adjust the sensor selecti on which is Menu 01(Air sensing;Air and Floor, or Floor only) 

Step 4, Press               to move to the next Menu and once y ou have all the menu options set, 

Setp 5, Press                to accept and store. 

Step 1, Turn the thermostat off by pressing              ;      

Step 2,  Press             , you will then see menu 01.    

POWER 

NEXT 

NEXT 

DONE 

DONE 

MENU 

This thermostat is a combination model which allows you  

to choose 3 different modes. 

A mode  =  Air Sensing Only(Has built  i n sensor) 
AF mode =  Air & Floor sensing( Floor probe must be installed) 
F mode =  Floor Sensing(Floor probe mus t  be installed) 

Menu # 

 01 

Mode/Sensor selection  

Switching Differential 

Air Temp Calibration  
Floor Temp Calibration  

Temperature Readout 

  (AF mode only) 

Maximum Floor Temp 

   ( AF mode only)  

Temperature Format 

Clock Format  

24 (default),  12- hour or 24-hour clock format 

02 

03 

04 

05 

06 

07 

08 

09 

10 

Feature 

Explanation 

Adjustment 

1 °C, 2°C....10°C ( 1°C by default)   

-1 °C  = decrease 1  °C ,  1 °C  =  increase 1 °C ... 

-1 °C  = decrease 1  °C ,  1 °C  =  increase 1 °C ... 

A= to show air temperature,  F=to show floor temperature, 

  A--F = to show both in 5 second intervals  

  20 °C~  40 °C  (40 °C  by default) 

  C  or    F 

A, AF, F 

(press up & down buttons to adjust) 

The number of degrees difference before switching.  

The default is 1°C which means the thermostat will switch  

the  heating on 0.5°C below the set temperature and will turn 

it off 0.5°C above the set temperature.With a 2°C differential    

the heating will switch on 1°C below the set temperature 

and will switch off 1°C above the set temperature.     

This is to recalibrate the air temperature if required. 
This is to recalibrate the floor temperature if required. 

This gives you the option to show the Air Temperature, 

Floor Temperature or to show both Air & Floor at intervals. 

This is to protect the floor surface. 

This alows the temperautre to be set to show °C or °F.  

You can select the clock to show in either 12 or 24 hour time 

5+2 / 7 Day Mode 

This allows you to program either 5 days at once, then the 

2 days of the weekend separately, or a full 7 days at the  

same time or 7 days separately 

Frost Protection 

on= activated,  off= deactivated 

01 = 5+2 day programmable 

02 = 7 day programmable 

This is to avoid your room temperature going below 5 °C   

Reviews: