Maintenance
Preventive and regular maintenance will ensure a long trouble free
life to your heater.
warning
• Never service heater while it is plugged in, operating or hot.
Severe burns or electrical shock can occur.
every 50 hours of operation: disassemble filter and wash with
clean oil, remove upper body parts and clean inside and ventilator
with compressed air, check correct attachment of H.T. connectors
to the electrodes and check H.T. cables, remove burner assembly,
clean and check electrode settings, adjust according to scheme
“GAP oF eleCTRoDeS”.
Flue connections diagram
A
6
2
D
C
1
B
5
E
VentilatiOn
description
a)
Minimal 39”
B)
Minimal 39”
c)
Avoid installing parts of the chimney horizontally. When
unavoidable, non-vertical short sections can be used as
long as the angle provides proper discharge
d)
diameter of chimney must not be reduced from outlet of
the unit
e)
Minimum 3’
1)
Anti-wind device provided with the heater
2)
Horizontal crossing with minimal upside angle pitch of 5°
3)
Chimney dimensions must adhere to local building codes
4)
Chimney inspection access if required by local codes
5)
external wall
6)
Chimney vent anti-wind cover
6 “