background image

10

eNeRCo GRoUP, INC. |Indirect Fired Portable Heater

operating Instructions and owner’s Manual

4000id Hd series indirect-Fired portable Heater parts list

nO.

stOcK no.

part list

01

G06185-9010

outlet cone

02

G06186

Combustion chamber

03

G06187

Combustion chamber support

04

G06188-9010

Upper body

05

G06189-9010

Cover inspection

06

G06190-9010

lower body

07

E10695-110

Motor 750W with condenser

08

e11242

Condenser 50 µF

09

G06191

Motor flange

10

T10267

Fan Ø550 18°

11

G06192-9010

Air flap

12

P30151

Inlet grille

13

I40330

“Tube BP 1/4”” FF l.420mm”

14

I20104

“Nipplo Fe 1/4”” MM”

15

02AC575-1

“Oil pre-heaters filter 1/4”””

19

G06104-9005

Filter support

20

I40329

“Tube BP 1/4”” FF l.260mm”

24

I40331

“Tube BP 1/4”” FF l.580mm”

25

I30696

Pascante l.290mm

26

I30737

“Nipplo OT 1/4”” M - M12x1,75 M”

27

G06193

Air adjustment panel

28

e20676

Thermostat plug 4P+T

30

C30367

Drain plug

31

G06243-9005

Fuel tank 57 US gal

32

I25019

“Drain plug M30x1,5 mm”

33

C30350

“oR Ø30 x 2,62 mm”

39

G06068-9005

Power lead hook

40

G00250

el. componets drawer

41

P50127

Control box cover

42

G06224-9010

Base

43

e50767

Thermostat TY95A 105 °C Campini

44

G06196

Centrifuge air fan

45

M20413

Bulb support

46

e50102

limit Thermostat

47

M20107

“Washer Ø5 x Ø15 x 1,5 mm”

48

e50104

Fan Thermostat

49

G06197

Blast tube

50

e20671

Terminal board

51

I40804

Air duct l=220 mm

52

e11229

Condenser 80 µF

53

G06154

electr. componets drawer

54

e20508

Fuse holder

55

e10313

Fuse (6x30) 20A

57

e20319

Terminal board

58

e20305

Terminal board

59

e10930

Transformer H.T. BRHAMA

60

e40121

Control box BRAHMA TGRD 92 120V

61

G06073

Plate for electrical components

62

E10102-P

Switch 0 - 1

63

e20640

Thermostat plug 3P+T

64

e20675

Plate plug 90° 3P + T

65

E10112-P

Switch 0 - 1

66

e30443

el. wire with plug and cable fastener

67

e11030

lamp 230V

68

T20357

“Nozzle 2,0 GPH 80° W”

69

G06225

Turbo disc

70

I33006

Nozzle support

71

G06226

Burner flange Ø 102mm

72

I31034

Nut M14

73

G06199

electrodes stirrup

74

e10215

electrodes

75

C30368

Cable protection Ø12 mm

76

G02076

H.T. Cable connect. l=1000 mm

77

I40192

Micropipe l=250 mm

79

e50328

ld ph. Unit FC13

80

T20441-1

Pump Suntek AT2 45 BK 2S - 120V

81

T20131

Solenoid spool  AT2 45 BK 2S Suntek 

-120V

82

T20130

Solenoid valve body torque Suntek

83

I20115

“Nipplo Fe 1/8”” MM”

84

e10513

Coupling K1

85

e11208

Condenser 20µF

86

E10677-110

Motor 200W with condenser - 120V

87

G06200-9010

Support fan and motor

88

C10328

leitungskanal

89

C30372

Cable protection Ø35 mm

90

G06201-9010

Support fan and motor

91

C10329

90° elbow connection

92

T10262

“Fan AP 160x55 F12,7”

93

C10326

Spiral fan

94

G06202

Shutter for air regulation

95

G06203

Air adjustment level

99

G06204

Air adjustment protection

100

e50327

Protection de la photoresistence

101

e20418

Stop button protection

102

G06227

Fitting support

103

G06222-9010

Support du pressostat

104

e50441

Presostat 100 Pa

105

I40332

Silicone pipe Ø4x9

Summary of Contents for 4000ID HD

Page 1: ...800 251 0001 INDIRECT FIRED PORTABLE HEATER heatstar BY eNERCO If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss...

Page 2: ...INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING NOT FOR HOME OR RECREATIONAL VEH...

Page 3: ...ey to take away the fumes see Ventilation on page 5 and connected to an electrical switchboard When the heater is connected to a flue pipe the flue pipe shall terminate in a vertical section at least...

Page 4: ...ing the reset button 1 Should the heater not start check that oil tank is full and depress reset button 1 Should the heater still not work please refer to chapter OBSERVED FAULTS CAUSES AND REMEDIES S...

Page 5: ...trodes and check H T cables remove burner assembly clean and check electrode settings adjust according to scheme GAP OF ELECTRODES Flue Connections Diagram A 6 2 D C 1 B 5 E Ventilation Description A...

Page 6: ...for cleanliness Replace H V transformer Flame control box defective Replace control box Photocell defective Clean or replace photocell Not enough or no fuel at all at burner Check state of motor pump...

Page 7: ...dels FU Fuse 20A IT Transformer H V LI1 Overheat Thermostat EV1 Solenoid Valve 1 EV2 Solenoid Valve 2 FO Photocell CO Condenser MV Fan Motor ST Electric pilot lamp RV Control TA Room Thermostat plug R...

Page 8: ...able Heaters 62 63 64 67 66 53 54 55 57 58 60 61 59 50 48 65 01 02 04 44 05 10 08 09 11 12 A 43 51 B 49 06 20 25 26 24 27 28 45 43 03 47 40 41 42 39 33 32 88 91 90 89 87 85 86 92 93 94 95 80 14 77 84...

Page 9: ...9 Operating Instructions and Owner s Manual ENERCO GROUP INC Indirect Fired Portable Heater 4000ID HD Series Indirect Fired Portable Heaters 110 111 119 118 117 116 115 114 113 120 112 121 37 38...

Page 10: ...9 Condenser 80 F 53 G06154 Electr componets drawer 54 E20508 Fuse holder 55 E10313 Fuse 6x30 20A 57 E20319 Terminal board 58 E20305 Terminal board 59 E10930 Transformer H T BRHAMA 60 E40121 Control bo...

Page 11: ...7 T20241 OR KIToil filter 108 T20242 Filter cartridge 109 T20442 Solenois valve cable 110 G06205 9005 Lifting frame 111 G06206 9005 Body support 112 G06207 9005 Front protection 113 G06208 Reinforceme...

Page 12: ...ortation prepaid within said one year period and found by the Company to have imperfections in material or workmanship If a part is damaged or missing call our Technical Support Department at 800 251...